Page 4 of 27 results (0.002 seconds)

CVSS: 4.3EPSS: 0%CPEs: 1EXPL: 0

An Out-of-bounds Read vulnerability exists in the DGN file reading procedure in Open Design Alliance Drawings SDK before 2022.11. Crafted data in a DGN file and lack of verification of input data can trigger a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Se presenta una vulnerabilidad de lectura fuera de límites en el procedimiento de lectura de archivos DGN en Open Design Alliance Drawings SDK versiones anteriores a 2022.11. Los datos diseñados en un archivo DGN y la falta de verificación de los datos de entrada pueden desencadenar una lectura más allá del final de un búfer asignado. • https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-1281 https://www.zerodayinitiative.com/advisories/ZDI-21-1291 https://www.zerodayinitiative.com/advisories/ZDI-21-1351 https://www.zerodayinitiative.com/advisories/ZDI-21-1357 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

A use-after-free issue exists in the DGN file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process. Se presenta un problema de uso de la memoria previamente liberada en el procedimiento de lectura de archivos DGN en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una corrupción de memoria o en una ejecución de código arbitrario, permitiendo a atacantes causar una condición de denegación de servicio o ejecutar código en el contexto del proceso actual This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-987 https://www.zerodayinitiative.com/advisories/ZDI-21-990 • CWE-416: Use After Free •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

An out-of-bounds read issue exists within the parsing of DXF files in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations. Se presenta un problema de lectura fuera de límites en el análisis de archivos DXF en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una lectura más allá del final de un búfer asignado y permite a atacantes causar una condición de denegación de servicio o leer información confidencial de las ubicaciones de memoria This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DXF files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-988 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. Se presenta un problema de escritura fuera de límites en el procedimiento de lectura de archivos DGN en Drawings SDK (versión 2022.4 y anteriores) resultando de una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una escritura más allá del final de un búfer asignado y permitir a atacantes causar una condición de denegación de servicio o ejecutar código en el contexto del proceso actual This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-989 • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. Se presenta un problema de comprobación inapropiada de condiciones inusuales o excepcionales en el análisis de archivos DGN de Drawings SDK (Versiones 2022.4 y anteriores) resultando en una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en varios problemas fuera de límites y permitir a atacantes causar una condición de denegación de servicio o ejecutar código en el contexto del proceso actual This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-983 https://www.zerodayinitiative.com/advisories/ZDI-21-985 • CWE-754: Improper Check for Unusual or Exceptional Conditions •