Page 4 of 33 results (0.005 seconds)

CVSS: 7.8EPSS: 6%CPEs: 30EXPL: 0

30 Jun 2017 — A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. Se ha descubierto un problema de agotamiento d... • http://www.securityfocus.com/bid/96414 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 10.0EPSS: 5%CPEs: 146EXPL: 0

03 Oct 2014 — Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. Vulnerabil... • http://download.schneider-electric.com/files?p_Reference=SEVD-2014-260-01&p_EnDocType=Software%20-%20Updates&p_File_Id=608959359&p_File_Name=SEVD-2014-260-01.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 24EXPL: 0

04 Apr 2013 — The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. ** EN DISPUTA ** Los modulos Schneider Electric M340 PLC permite a atacantes remotos causar una denegación de servicios (consumo de recursos) a través de vectores no especificados. NOTA: El... • http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf • CWE-400: Uncontrolled Resource Consumption •