Page 4 of 17 results (0.001 seconds)

CVSS: 7.8EPSS: 0%CPEs: 30EXPL: 0

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. Se ha descubierto un problema de agotamiento de recursos en Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H y BMXP342030H. Un atacante remoto podría enviar un conjunto de paquetes manipulados al PLC para congelarlo, lo que requeriría que el operador presionase físicamente el botón reset en el PLC para recuperarlo. • http://www.securityfocus.com/bid/96414 https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 10.0EPSS: 0%CPEs: 146EXPL: 0

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. Vulnerabilidad de salto de directorio en SchneiderWEB en los módulos Schneider Electric Modicon PLC Ethernet 140CPU65x Exec anterior a 5.5, 140NOC78x Exec anterior a 1.62, 140NOE77x Exec anterior a 6.2, BMXNOC0401 anterior a 2.05, BMXNOE0100 anterior a 2.9, BMXNOE0110x Exec anterior a 6.0, TSXETC101 Exec anterior a 2.04, TSXETY4103x Exec anterior a 5.7, TSXETY5103x Exec anterior a 5.9, TSXP57x ETYPort Exec anterior a 5.7, y TSXP57x Ethernet Copro Exec anterior a 5.5 permite a atacantes remotos visitar recursos arbitrarios a través de una solicitud HTTP manipulada. • http://download.schneider-electric.com/files?p_Reference=SEVD-2014-260-01&p_EnDocType=Software%20-%20Updates&p_File_Id=608959359&p_File_Name=SEVD-2014-260-01.pdf http://www.securityfocus.com/bid/70193 https://ics-cert.us-cert.gov/advisories/ICSA-14-273-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •