Page 4 of 19 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 2

A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una Denegación de Servicio al enviar parámetros Debug no válidos hacia el controlador mediante Modbus. • https://github.com/yanissec/CVE-2018-7854 https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0765 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una Denegación de Servicio cuando se leen bloques de memoria física no válidos en el controlador sobre protocolo Modbus. • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0764 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 2

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus CWE-200: Existe una vulnerabilidad de Exposición de Información en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar la divulgación de información SNMP cuando se leen archivos desde el controlador sobre protocolo Modbus. • https://github.com/yanissec/CVE-2018-7848 https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0740 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 7.5EPSS: 0%CPEs: 38EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium. Una CWE-754: Existe una vulnerabilidad de Comprobación Inapropiada para condiciones inusuales o excepcionales, que podría generar una posible Denegación de Servicio cuando se envían tramas Modbus específicas hacia el controlador en los productos: Modicon M340 - versiones de firmware anteriores a la V3.01, Modicon M580 - versiones de firmware anteriores a V2.80, y todas las versiones de firmware de Modicon Quantum y Modicon Premium. • http://www.securityfocus.com/bid/109004 https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05 • CWE-754: Improper Check for Unusual or Exceptional Conditions •