Page 4 of 45 results (0.006 seconds)

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 7.5EPSS: 8%CPEs: 50EXPL: 0

The in-memory certificate cache in strongSwan before 5.9.4 has a remote integer overflow upon receiving many requests with different certificates to fill the cache and later trigger the replacement of cache entries. The code attempts to select a less-often-used cache entry by means of a random number generator, but this is not done correctly. Remote code execution might be a slight possibility. La caché de certificados en memoria en strongSwan versiones anteriores a 5.9.4, presenta un desbordamiento de enteros remoto al recibir muchas peticiones con diferentes certificados para llenar la caché y posteriormente desencadenar la sustitución de las entradas de la caché. El código intenta seleccionar una entrada de caché menos usada mediante un generador de números aleatorios, pero esto no es realizado correctamente. • https://cert-portal.siemens.com/productcert/pdf/ssa-539476.pdf https://github.com/strongswan/strongswan/releases/tag/5.9.4 https://lists.debian.org/debian-lts-announce/2021/10/msg00014.html https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5FJSATD2R2XHTG4P63GCMQ2N7EWKMME5 https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WQSQ3BEC22NF4NCDZVCT4P3Q2ZIAJXGJ https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/mes • CWE-190: Integer Overflow or Wraparound •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device. • https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf • CWE-287: Improper Authentication •

CVSS: 7.5EPSS: 0%CPEs: 157EXPL: 0

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condición de denegación de servicio. La vulnerabilidad puede activarse si se envía una gran cantidad de paquetes de restablecimiento de DCP al dispositivo • https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 https://cert-portal.siemens.com/productcert/html/ssa-599968.html • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.8EPSS: 0%CPEs: 63EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. • https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •