CVE-2023-24992 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24992
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19814) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24991 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24991
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19813) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24990 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24990
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19812) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24989 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24989
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19811) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24988 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24988
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19810) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24987 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24987
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19809) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24986 – Siemens Tecnomatix Plant Simulation SPP File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24986
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19808) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24985 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24985
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19807) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24984 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24984
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19806) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2023-24983 – Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-24983
14 Feb 2023 — A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19805) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this... • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-787: Out-of-bounds Write •