Page 4 of 45 results (0.006 seconds)

CVSS: 7.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.3.0.1), Teamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0.12), Teamcenter Visualization V14.0 (Todas las versiones), Teamcenter Visualization V14.1 ( Todas las versiones &lt; V14.1.0.11), Teamcenter Visualization V14.2 (todas las versiones &lt; V14.2.0.6), Teamcenter Visualization V14.3 (todas las versiones &lt; V14.3.0.1). La aplicación afectada es vulnerable al Desbordamiento del Búfer mientras analiza archivos WRL especialmente manipulados. • https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.3.0.1), Teamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0.12), Teamcenter Visualization V14.0 (Todas las versiones), Teamcenter Visualization V14.1 ( Todas las versiones &lt; V14.1.0.11), Teamcenter Visualization V14.2 (todas las versiones &lt; V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones &lt; V14.3.0.1). La aplicación afectada es vulnerable al Desbordamiento del Búfer al analizar archivos WRL especialmente manipulados. • https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of SPP files. • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20432) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of SPP files. • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20433) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of SPP files. • https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •