Page 4 of 20 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

curl 7.62.0 through 7.70.0 is vulnerable to an information disclosure vulnerability that can lead to a partial password being leaked over the network and to the DNS server(s). curl versiones 7.62.0 hasta 7.70.0, es susceptible a una vulnerabilidad de divulgación de información que puede conllevar a que una contraseña parcial sea filtrada a través de la red y a servidor(es) DNS A flaw was found in libcurl. A part of a password may be prepended to the host name before the host name is resolved, leading to a leak of the partial password over the network and to DNS servers. This highest threat from this vulnerability is to data confidentiality. • https://cert-portal.siemens.com/productcert/pdf/ssa-200951.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf https://curl.se/docs/CVE-2020-8169.html https://hackerone.com/reports/874778 https://www.debian.org/security/2021/dsa-4881 https://access.redhat.com/security/cve/CVE-2020-8169 https://bugzilla.redhat.com/show_bug.cgi?id=1847916 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 5.9EPSS: 0%CPEs: 36EXPL: 0

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf https://www.us-cert.gov/ics/advisories/icsa-19-344-04 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVSS: 7.5EPSS: 0%CPEs: 125EXPL: 0

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7" y 15" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4" - 22" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles móviles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf • CWE-125: Out-of-bounds Read •

CVSS: 10.0EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known. • http://www.securityfocus.com/bid/106194 https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf • CWE-284: Improper Access Control CWE-287: Improper Authentication •

CVSS: 10.0EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it. • http://www.securityfocus.com/bid/103576 https://cert-portal.siemens.com/productcert/pdf/ssa-110922.pdf • CWE-287: Improper Authentication CWE-303: Incorrect Implementation of Authentication Algorithm •