CVSS: 7.8EPSS: 0%CPEs: 54EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V17 (Todas las versiones anteriores a= V17 Update 4), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 6). El componente afectado almacena las credenciales de una cuenta del sistema local en un archivo de proyecto potencialmente accesible al público utilizando un algoritmo de cifrado obsoleto. • https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf • CWE-312: Cleartext Storage of Sensitive Information CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory •

CVSS: 8.8EPSS: 0%CPEs: 53EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 6). El hash de la contraseña de una cuenta de usuario local en el servidor remoto podría concederse a través de la API pública a un usuario del sistema afectado. • https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-522: Insufficiently Protected Credentials •

CVSS: 7.1EPSS: 0%CPEs: 14EXPL: 0

In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions. En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creación de un enlace simbólico CmDongles diseñado sobrescribirá el archivo enlazado sin comprobar los permisos • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf https://www.wibu.com/us/support/security-advisories.html • CWE-59: Improper Link Resolution Before File Access ('Link Following') •

CVSS: 5.5EPSS: 0%CPEs: 21EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 5). Los sistemas afectados almacenan información sensible en archivos de registro. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-532: Insertion of Sensitive Information into Log File •

CVSS: 7.7EPSS: 0%CPEs: 39EXPL: 0

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. Se ha identificado una vulnerabilidad en OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a la versión a la versión V9.0 Upd4), OpenPCS 7 V9.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones), SIMATIC BATCH V9. 1 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión a la versión V16 Update 6), SIMATIC NET PC Software V17 (Todas las versiones anteriores a la versión a la versión V17 SP1), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9. 0 (Todas las versiones anteriores a la versión a la versión V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a la versión a la versión V9.1 SP1), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones), SIMATIC Route Control V9. 1 (Todas las versiones), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a la versión a la versión V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a la versión a la versión V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a la versión a la versión V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP2 Update 5). Al descargar archivos, los sistemas afectados no neutralizan correctamente los elementos especiales dentro del nombre de la ruta. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •