CVE-2022-21748
https://notcve.org/view.php?id=CVE-2022-21748
In telephony, there is a possible information disclosure due to a missing permission check. This could lead to local information disclosure with User execution privileges needed. User interaction is needed for exploitation. Patch ID: ALPS06511030; Issue ID: ALPS06511030. En telephony se presenta una posible divulgación de información debido a una falta de comprobación de permisos. • https://corp.mediatek.com/product-security-bulletin/June-2022 • CWE-862: Missing Authorization •
CVE-2022-21747
https://notcve.org/view.php?id=CVE-2022-21747
In imgsensor, there is a possible out of bounds read due to a missing bounds check. This could lead to local denial of service with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06478078; Issue ID: ALPS06478078. En imgsensor, se presenta una posible lectura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/June-2022 • CWE-125: Out-of-bounds Read •
CVE-2022-21745
https://notcve.org/view.php?id=CVE-2022-21745
In WIFI Firmware, there is a possible memory corruption due to a use after free. This could lead to remote escalation of privilege, when devices are connecting to the attacker-controllable Wi-Fi hotspot, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06468872; Issue ID: ALPS06468872. En WIFI Firmware, se presenta una posible corrupción de memoria debido a un uso de memoria previamente liberada. • https://corp.mediatek.com/product-security-bulletin/June-2022 • CWE-416: Use After Free •
CVE-2022-21743
https://notcve.org/view.php?id=CVE-2022-21743
In ion, there is a possible use after free due to an integer overflow. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06371108; Issue ID: ALPS06371108. En ion, se presenta un posible uso de memoria previamente liberada debido a un desbordamiento de enteros. • https://corp.mediatek.com/product-security-bulletin/May-2022 • CWE-190: Integer Overflow or Wraparound •
CVE-2022-20111
https://notcve.org/view.php?id=CVE-2022-20111
In ion, there is a possible use after free due to incorrect error handling. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06366069; Issue ID: ALPS06366069. En ion, se presenta un posible uso de memoria previamente liberada debido a un manejo incorrecto de errores. • https://corp.mediatek.com/product-security-bulletin/May-2022 • CWE-755: Improper Handling of Exceptional Conditions •