Page 45 of 333 results (0.005 seconds)

CVSS: 4.4EPSS: 0%CPEs: 38EXPL: 0

In CCCI, there is a possible out of bounds read due to a missing bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06641673; Issue ID: ALPS06641687. En CCCI, Se presenta una posible lectura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/July-2022 • CWE-125: Out-of-bounds Read •

CVSS: 6.7EPSS: 0%CPEs: 38EXPL: 0

In CCCI, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06641673; Issue ID: ALPS06641653. En CCCI, es posible sea producida una escritura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/July-2022 • CWE-787: Out-of-bounds Write •

CVSS: 6.7EPSS: 0%CPEs: 38EXPL: 0

In CCCI, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06641673; Issue ID: ALPS06641673. En CCCI, es posible sea producida una escritura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/July-2022 • CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 73EXPL: 0

In Modem 2G/3G CC, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution when decoding combined FACILITY with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00803883; Issue ID: MOLY00803883. En Modem 2G/3G CC, es posible sea producida una escritura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/July-2022 • CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 73EXPL: 0

In Modem 2G RR, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution when decoding GPRS Packet Neighbour Cell Data (PNCD) improper neighbouring cell size with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00810064; Issue ID: ALPS06641626. En Modem 2G RR, es posible sea producida una escritura fuera de límites debido a una falta de comprobación de límites. • https://corp.mediatek.com/product-security-bulletin/July-2022 • CWE-787: Out-of-bounds Write •