CVE-2023-32885
https://notcve.org/view.php?id=CVE-2023-32885
02 Jan 2024 — In display drm, there is a possible memory corruption due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07780685; Issue ID: ALPS07780685. En display drm, existe una posible corrupción de la memoria debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2023-32884
https://notcve.org/view.php?id=CVE-2023-32884
02 Jan 2024 — In netdagent, there is a possible information disclosure due to an incorrect bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07944011; Issue ID: ALPS07944011. En netdagent, existe una posible divulgación de información debido a una verificación de los límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2023-32883
https://notcve.org/view.php?id=CVE-2023-32883
02 Jan 2024 — In Engineer Mode, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08282249; Issue ID: ALPS08282249. En Engineer Mode, existe una posible escritura fuera de los límites debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-787: Out-of-bounds Write •

CVE-2023-32882
https://notcve.org/view.php?id=CVE-2023-32882
02 Jan 2024 — In battery, there is a possible memory corruption due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08308616. En la batería, existe una posible corrupción de la memoria debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-787: Out-of-bounds Write •

CVE-2023-32881
https://notcve.org/view.php?id=CVE-2023-32881
02 Jan 2024 — In battery, there is a possible information disclosure due to an integer overflow. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08308080. En battery, existe una posible divulgación de información debido a un desbordamiento de enteros. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-190: Integer Overflow or Wraparound •

CVE-2023-32880
https://notcve.org/view.php?id=CVE-2023-32880
02 Jan 2024 — In battery, there is a possible information disclosure due to a missing bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08308076. En la battery, existe una posible divulgación de información debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-125: Out-of-bounds Read •

CVE-2023-32879
https://notcve.org/view.php?id=CVE-2023-32879
02 Jan 2024 — In battery, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08308064. En battery, existe una posible escritura fuera de los límites debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-787: Out-of-bounds Write •

CVE-2023-32878
https://notcve.org/view.php?id=CVE-2023-32878
02 Jan 2024 — In battery, there is a possible information disclosure due to a missing bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08307992. En battery, existe una posible divulgación de información debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-125: Out-of-bounds Read •

CVE-2023-32877
https://notcve.org/view.php?id=CVE-2023-32877
02 Jan 2024 — In battery, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308070; Issue ID: ALPS08308070. En battery, existe una posible escritura fuera de los límites debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-787: Out-of-bounds Write •

CVE-2023-32876
https://notcve.org/view.php?id=CVE-2023-32876
02 Jan 2024 — In keyInstall, there is a possible information disclosure due to a missing bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08308612; Issue ID: ALPS08308612. En keyInstall, existe una posible divulgación de información debido a una verificación de los límites faltantes. • https://corp.mediatek.com/product-security-bulletin/January-2024 • CWE-125: Out-of-bounds Read •