Page 5 of 24 results (0.007 seconds)

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe una derivación de puntero nulo al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-221 https://www.zerodayinitiative.com/advisories/ZDI-21-222 • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe un problema de confusión de tipos al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-219 • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. Se detectó un problema en Open Design Alliance Drawings SDK versiones anteriores a 2021.11. Se presenta una vulnerabilidad de desbordamiento del búfer en la región stack de la memoria cuando la operación de recuperación se ejecuta con archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-220 https://www.zerodayinitiative.com/advisories/ZDI-21-240 https://www.zerodayinitiative.com/advisories/ZDI-21-243 • CWE-787: Out-of-bounds Write •

CVSS: 8.5EPSS: 0%CPEs: 3EXPL: 0

Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls. Siemens COMOS antes de v9.1 Patch 413, v9.2 antes de Update 03 Patch 023 y v10.0 antes de Patch 005 permite a usuarios remotos autenticados obtener acceso a la base de datos administrativa a través de llamadas a métodos no especificados. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-312568.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-227-01.pdf • CWE-264: Permissions, Privileges, and Access Controls •