Page 5 of 48 results (0.001 seconds)

CVSS: 7.1EPSS: 0%CPEs: 14EXPL: 0

In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions. En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creación de un enlace simbólico CmDongles diseñado sobrescribirá el archivo enlazado sin comprobar los permisos • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf https://www.wibu.com/us/support/security-advisories.html • CWE-59: Improper Link Resolution Before File Access ('Link Following') •

CVSS: 5.5EPSS: 0%CPEs: 21EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 5). Los sistemas afectados almacenan información sensible en archivos de registro. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-532: Insertion of Sensitive Information into Log File •

CVSS: 9.9EPSS: 0%CPEs: 48EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 5). Las operaciones de archivo legítimas en el servidor web de los sistemas afectados no neutralizan correctamente los elementos especiales dentro de la ruta de acceso. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 8.8EPSS: 0%CPEs: 15EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.X (Todas las versiones anteriores a V9.1 SP2), SIMATIC PDM (Todas las versiones anteriores a V9.2 SP2), SIMATIC STEP 7 V5.X (Todas las versiones anteriores a V5.7), SINAMICS STARTER (que contiene la versión OEM de STEP 7) (Todas las versiones anteriores a V5.4 SP2 HF1). Un directorio que contiene metafichas relevantes para las configuraciones de los dispositivos tiene permisos de escritura. • https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 7.8EPSS: 0%CPEs: 14EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 versiones V8.2 y anteriores (Todas las versiones), SIMATIC PCS 7 versiones V9.0 (Todas las versiones anteriores a V9.0 SP3), SIMATIC PDM (Todas las versiones anteriores a V9.2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.6 SP2 HF3), SINAMICS STARTER (que contiene la versión OEM de STEP 7) (Todas las versiones anteriores a V5.4 HF2). El software afectado contiene una vulnerabilidad de desbordamiento de búfer mientras se manejan determinados archivos que podría permitir a un atacante local desencadenar una condición de denegación de servicio o potencialmente conllevar a una ejecución de código remota • https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •