Page 5 of 99 results (0.011 seconds)

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Solid Edge SE2023 para todas las versiones anteriores a la V223.0 Update 7. La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo PAR especialmente diseñado. • https://cert-portal.siemens.com/productcert/pdf/ssa-811403.pdf • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 21EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process. Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones inferiores a V14.2.0.5), Solid Edge SE2022 (Todas las versiones inferiores a V222.0 Update 13), Solid Edge SE2023 (Todas las versiones inferiores a V223.0 Update 4), Teamcenter Visualization V13. 2 (Todas las versiones inferiores a V13.2.0.15), Teamcenter Visualization V13.3 (Todas las versiones inferiores a V13.3.0.11), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.5). La aplicación afectada contiene una vulnerabilidad "use-after-free" que podría activarse al analizar un archivo ASM especialmente diseñado. • https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf • CWE-416: Use After Free •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of STP files. • https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •

CVSS: 5.5EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426) This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of OBJ files. • https://cert-portal.siemens.com/productcert/pdf/ssa-932528.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 5EXPL: 0

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150), Solid Edge SE2022 (All versions < V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. • https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf • CWE-125: Out-of-bounds Read •