CVSS: 5.5EPSS: 0%CPEs: 57EXPL: 0

In ion driver, there is a possible information disclosure due to an incorrect bounds check. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06171689; Issue ID: ALPS06171689. En ion driver, se presenta una posible divulgación de información debido a una comprobación de límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-20: Improper Input Validation •

CVSS: 5.5EPSS: 0%CPEs: 58EXPL: 0

In ion driver, there is a possible information disclosure due to an incorrect bounds check. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06171705; Issue ID: ALPS06171705. En ion driver, se presenta una posible divulgación de información debido a una comprobación de límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-20: Improper Input Validation •

CVSS: 4.4EPSS: 0%CPEs: 33EXPL: 0

In vcu driver, there is a possible information disclosure due to a use after free. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06171675; Issue ID: ALPS06171675. En vcu driver, se presenta una posible divulgación de información debido a un uso de memoria previamente liberada. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-416: Use After Free •

CVSS: 5.5EPSS: 0%CPEs: 28EXPL: 0

In ion driver, there is a possible information disclosure due to an incorrect bounds check. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05862991; Issue ID: ALPS05862991. En ion driver, se presenta una posible divulgación de información debido a una comprobación de límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-20: Improper Input Validation •

CVSS: 4.4EPSS: 0%CPEs: 41EXPL: 0

In cmdq driver, there is a possible out of bounds read due to an incorrect bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05747150; Issue ID: ALPS05747150. En cmdq driver, se presenta una posible lectura fuera de límites debido a una comprobación de límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-125: Out-of-bounds Read •