Page 57 of 296 results (0.010 seconds)

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

On QFX and PTX Series, receipt of a malformed packet for J-Flow sampling might crash the FPC (Flexible PIC Concentrator) process which causes all interfaces to go down. By continuously sending the offending packet, an attacker can repeatedly crash the FPC process causing a sustained Denial of Service (DoS). This issue affects both IPv4 and IPv6 packet processing. Affected releases are Juniper Networks Junos OS on QFX and PTX Series: 17.4 versions prior to 17.4R2-S1, 17.4R3; 18.1 versions prior to 18.1R3-S1; 18.2 versions prior to 18.2R1-S3, 18.2R2; 17.2X75 versions prior to 17.2X75-D91, 17.2X75-D100. En las series QFX y PTX, la recepción de un paquete mal formado para el muestreo de J-Flow podría provocar el cierre inesperado del proceso FPC (Flexible PIC Concentrator), que provoca que todas las interfaces se caigan. • http://www.securityfocus.com/bid/106556 https://kb.juniper.net/JSA10914 • CWE-19: Data Processing Errors •

CVSS: 7.5EPSS: 1%CPEs: 75EXPL: 0

Receipt of a malformed packet on MX Series devices with dynamic vlan configuration can trigger an uncontrolled recursion loop in the Broadband Edge subscriber management daemon (bbe-smgd), and lead to high CPU usage and a crash of the bbe-smgd service. Repeated receipt of the same packet can result in an extended denial of service condition for the device. Affected releases are Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S1; 16.2 versions prior to 16.2R2-S7; 17.1 versions prior to 17.1R2-S10, 17.1R3; 17.2 versions prior to 17.2R3; 17.3 versions prior to 17.3R3-S1; 17.4 versions prior to 17.4R2; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. La recepción de un paquete mal formado en dispositivos MX Series con una configuración vlan dinámica puede desencadenar un bucle de recursión no controlado en el demonio de gestión de suscriptores Broadband Edge (bbe-smgd) y conducir a un alto uso de CPU y el cierre inesperado del servicio bbe-smgd. La recepción repetida del mismo paquete puede resultar en una condición de denegación de servicio (DoS) extendida para los dispositivos. • http://www.securityfocus.com/bid/106541 https://kb.juniper.net/JSA10900 https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/RMKFSHPMOZL7MDWU5RYOTIBTRWSZ4Z6X https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W7CPKBW4QZ4VIY4UXIUVUSHRJ4R2FROE • CWE-674: Uncontrolled Recursion •

CVSS: 5.5EPSS: 0%CPEs: 95EXPL: 0

A vulnerability in the SRX Series Service Gateway allows deleted dynamic VPN users to establish dynamic VPN connections until the device is rebooted. A deleted dynamic VPN connection should be immediately disallowed from establishing new VPN connections. Due to an error in token caching, deleted users are allowed to connect once a previously successful dynamic VPN connection has been established. A reboot is required to clear the cached authentication token. Affected releases are Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D75; 15.1X49 versions prior to 15.1X49-D150; 17.3 versions prior to 17.3R3; 17.4 versions prior to 17.4R2; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. • http://www.securityfocus.com/bid/106668 https://kb.juniper.net/JSA10915 • CWE-613: Insufficient Session Expiration •

CVSS: 5.5EPSS: 0%CPEs: 14EXPL: 0

On EX2300 and EX3400 series, high disk I/O operations may disrupt the communication between the routing engine (RE) and the packet forwarding engine (PFE). In a virtual chassis (VC) deployment, this issue disrupts communication between the VC members. This issue does not affect other Junos platforms. Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R2-S2, 18.1R3; 18.2 versions prior to 18.2R2. En las series EX2300 y EX3400, las operaciones high disk I/O podrían interrumpir las comunicaciones entre el motor de enrutamiento (RE) y el motor de reenvío de paquetes (PFE). • http://www.securityfocus.com/bid/106548 https://kb.juniper.net/JSA10909 •

CVSS: 9.8EPSS: 0%CPEs: 20EXPL: 0

On EX2300 and EX3400 series, stateless firewall filter configuration that uses the action 'policer' in combination with other actions might not take effect. When this issue occurs, the output of the command: show pfe filter hw summary will not show the entry for: RACL group Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. This issue affect both IPv4 and IPv6 firewall filter. En las series EX2300 y EX3400, la configuración sin estado del filtro del firewall que emplea la acción "policer" junto con otras acciones podría no aplicarse. Cuando este problema ocurre, el resultado del comando show pfe filter hw summary no mostrará la entrada para: RACL group. • http://www.securityfocus.com/bid/106669 https://kb.juniper.net/JSA10901 https://www.juniper.net/documentation/en_US/junos/topics/reference/command-summary/show-pfe-filter.html • CWE-794: Incomplete Filtering of Multiple Instances of Special Elements •