CVE-2021-33011
https://notcve.org/view.php?id=CVE-2021-33011
All versions of the afffected TOYOPUC-PC10 Series,TOYOPUC-Plus Series,TOYOPUC-PC3J/PC2J Series, TOYOPUC-Nano Series products may not be able to properly process an ICMP flood, which may allow an attacker to deny Ethernet communications between affected devices. Todas las versiones de los productos afectados de la serie TOYOPUC-PC10, la serie TOYOPUC-Plus, la serie TOYOPUC-PC3J/PC2J y la serie TOYOPUC-Nano podrían no ser capaces de procesar apropiadamente una ICMP flood, que podría permitir a un atacante denegar las comunicaciones Ethernet entre los dispositivos afectados • https://us-cert.cisa.gov/ics/advisories/icsa-21-245-02 • CWE-770: Allocation of Resources Without Limits or Throttling •
CVE-2021-27477
https://notcve.org/view.php?id=CVE-2021-27477
When JTEKT Corporation TOYOPUC PLC versions PC10G-CPU, 2PORT-EFR, Plus CPU, Plus EX, Plus EX2, Plus EFR, Plus EFR2, Plus 2P-EFR, PC10P-DP, PC10P-DP-IO, Plus BUS-EX, Nano 10GX, Nano 2ET,PC10PE, PC10PE-16/16P, PC10E, FL/ET-T-V2H, PC10B,PC10B-P, Nano CPU, PC10P, and PC10GE receive an invalid frame, the outside area of a receive buffer for FL-net are overwritten. As a result, the PLC CPU detects a system error, and the affected products stop. Cuando JTEKT Corporation TOYOPUC PLC versiones PC10G-CPU, 2PORT-EFR, Plus CPU, Plus EX, Plus EX2, Plus EFR, Plus EFR2, Plus 2P-EFR, PC10P-DP, PC10P-DP-IO, Plus BUS-EX, Nano 10GX, Nano 2ET,PC10PE, PC10PE-16/16P, PC10E, FL/ET-T-V2H, PC10B,PC10B-P, Nano CPU, PC10P y PC10GE reciben una trama no válida, el área exterior de un búfer de recepción para FL-net se sobrescribe. Como resultado, la CPU del PLC detecta un error del sistema y los productos afectados se detienen • https://us-cert.cisa.gov/ics/advisories/icsa-21-180-04 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •
CVE-2021-27458
https://notcve.org/view.php?id=CVE-2021-27458
If Ethernet communication of the JTEKT Corporation TOYOPUC product series’ (TOYOPUC-PC10 Series: PC10G-CPU TCC-6353: All versions, PC10GE TCC-6464: All versions, PC10P TCC-6372: All versions, PC10P-DP TCC-6726: All versions, PC10P-DP-IO TCC-6752: All versions, PC10B-P TCC-6373: All versions, PC10B TCC-1021: All versions, PC10B-E/C TCU-6521: All versions, PC10E TCC-4737: All versions; TOYOPUC-Plus Series: Plus CPU TCC-6740: All versions, Plus EX TCU-6741: All versions, Plus EX2 TCU-6858: All versions, Plus EFR TCU-6743: All versions, Plus EFR2 TCU-6859: All versions, Plus 2P-EFR TCU-6929: All versions, Plus BUS-EX TCU-6900: All versions; TOYOPUC-PC3J/PC2J Series: FL/ET-T-V2H THU-6289: All versions, 2PORT-EFR THU-6404: All versions) are left in an open state by an attacker, Ethernet communications cannot be established with other devices, depending on the settings of the link parameters. Si la comunicación Ethernet de la serie de productos TOYOPUC de JTEKT Corporation" (Serie TOYOPUC-PC10: PC10G-CPU TCC-6353: Todas las versiones, PC10GE TCC-6464: Todas las versiones, PC10P TCC-6372: Todas las versiones, PC10P-DP TCC-6726: Todas las versiones, PC10P-DP-IO TCC-6752: Todas las versiones, PC10B-P TCC-6373: Todas las versiones, PC10B TCC-1021: Todas las versiones, PC10B-E/C TCU-6521: Todas las versiones, PC10E TCC-4737: Todas las versiones; Serie TOYOPUC-Plus: Plus CPU TCC-6740: Todas las versiones, Plus EX TCU-6741: Todas las versiones, Plus EX2 TCU-6858: Todas las versiones, Plus EFR TCU-6743: Todas las versiones, Plus EFR2 TCU-6859: Todas las versiones, Plus 2P-EFR TCU-6929: Todas las versiones, Plus BUS-EX TCU-6900: Todas las versiones; Serie TOYOPUC-PC3J/PC2J: FL/ET-T-V2H THU-6289: Todas las versiones, 2PORT-EFR THU-6404: Todas las versiones) son dejadas en estado abierto por un atacante, las comunicaciones Ethernet no pueden ser establecidas con otros dispositivos, dependiendo de la configuración de los parámetros del enlace • https://us-cert.cisa.gov/ics/advisories/icsa-21-103-03 • CWE-404: Improper Resource Shutdown or Release •