Page 6 of 30 results (0.005 seconds)

CVSS: 6.1EPSS: 0%CPEs: 7EXPL: 0

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. Dispositivos Siemens SIMATIC S7-1200 CPU PLC con firmware anterior a 4.0 permiten a atacantes remotos causar una denegación de servicio (transición de modo defecto) a través de paquetes PROFINET manipulados, una vulnerabilidad diferente a CVE-2014-2253. • http://ics-cert.us-cert.gov/advisories/ICSA-14-079-02 http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-654382.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-654382.pdf • CWE-399: Resource Management Errors •

CVSS: 7.8EPSS: 0%CPEs: 18EXPL: 0

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port). Siemens SIMATIC S7-1200 PLCs v2.x y v3.x ermite a atacantes remotos causar una denegación de servicios (transición de modo defecto e interrupción de control) a través de paquetes TCP manipulados dirigidos al puerto 102 (conocido como puerto ISO-TSAP). • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf •

CVSS: 7.8EPSS: 0%CPEs: 18EXPL: 0

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). Siemens SIMATIC S7-1200 PLCs v2.x y v3.x permite a atacantes remotos causar una denegación de servicio mediante paquetes especialmente creados hacia el puerto UDP 161 (puerto SNMP) • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf •

CVSS: 4.3EPSS: 0%CPEs: 18EXPL: 0

Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. Vulnerabilidad de ejecución de secuencias de comandos en sitios cruzados (XSS) en el servidor web SIMATIC S7-1200 PLCs v2.x hasta v3.0.1 permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de una URI específicamente construida. • http://en.securitylab.ru/lab/PT-2012-50 http://osvdb.org/86130 http://secunia.com/advisories/50816 http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 4.3EPSS: 0%CPEs: 18EXPL: 0

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate. El PLC siemens SIMATIC S7-1200 2.x no protege de forma adecuada la clave privada del certificado de SIMATIC CONTROLLER Certification Authority, lo que permitiría a atacantes remotos espiar el servidor Web S7-1200 usando esta clave para crear certificados falsificados. • http://en.securitylab.ru/lab/PT-2012-48 http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf • CWE-295: Improper Certificate Validation •