CVE-2022-22172 – Junos OS and Junos OS Evolved: An l2cpd memory leak can occur when specific LLDP packets are received leading to a DoS
https://notcve.org/view.php?id=CVE-2022-22172
A Missing Release of Memory after Effective Lifetime vulnerability in the Layer-2 control protocols daemon (l2cpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated adjacent attacker to cause a memory leak. Continued exploitation can lead to memory exhaustion and thereby a Denial of Service (DoS). This issue occurs when specific LLDP packets are received. The impact of the l2cpd cores is that if any of the stp protocols (rstp, mstp or vstp) is used then stp re-converges and traffic loss will occur during that time. Also if any services depend on LLDP state (like PoE or VoIP device recognition) then these will also be affected. • https://kb.juniper.net/JSA11278 • CWE-401: Missing Release of Memory after Effective Lifetime •
CVE-2022-22171 – Junos OS: Specific packets over VXLAN cause FPC reset
https://notcve.org/view.php?id=CVE-2022-22171
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a Denial of Service (DoS) by sending specific packets over VXLAN which cause the PFE to reset. This issue affects: Juniper Networks Junos OS 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect versions of Junos OS prior to 19.4R1. Una vulnerabilidad de comprobación inapropiada de Condiciones Inusuales o Excepcionales en el Motor de Reenvío de Paquetes (PFE) de Juniper Networks Junos OS permite a un atacante no autenticado conectado a la red causar una Denegación de Servicio (DoS) mediante el envío de paquetes específicos a través de VXLAN que causan el reinicio del PFE. Este problema afecta a: Juniper Networks Junos OS versiones 19.4 anteriores a 19.4R3-S7; versiones 20.1 anteriores a 20.1R3-S3; versiones 20.2 anteriores a 20.2R3-S3; versiones 20.3 anteriores a 20.3R3-S2; versiones 20.4 anteriores a 20.4R3-S1; versiones 21.1 anteriores a 21.1R3; versiones 21.2 anteriores a 21.2R2; versiones 21.3 anteriores a 21.3R1-S1, 21.3R2. • https://kb.juniper.net/JSA11277 • CWE-754: Improper Check for Unusual or Exceptional Conditions •
CVE-2022-22170 – Junos OS: Specific packets over VXLAN cause FPC memory leak and ultimately reset
https://notcve.org/view.php?id=CVE-2022-22170
A Missing Release of Resource after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a Denial of Service (DoS) by sending specific packets over VXLAN which cause heap memory to leak and on exhaustion the PFE to reset. The heap memory utilization can be monitored with the command: user@host> show chassis fpc This issue affects: Juniper Networks Junos OS 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2. This issue does not affect versions of Junos OS prior to 19.4R1. Una vulnerabilidad de Falta de Liberación de Recursos Después del Tiempo de Vida Efectivo en el Motor de Reenvío de Paquetes (PFE) del Sistema Operativo Junos de Juniper Networks permite a un atacante no autenticado en red causar una denegación de servicio (DoS) mediante el envío de paquetes específicos a través de VXLAN que causan una pérdida de memoria de la pila y, al agotarse, el PFE es reiniciado. El uso de la memoria de la pila puede supervisarse con el comando: user@host) show chassis fpc Este problema afecta a: Juniper Networks Junos OS 19.4 versiones anteriores a 19.4R2-S6, 19.4R3-S6; 20.1 versiones anteriores a 20.1R3-S2; versiones 20.2 anteriores a 20.2R3-S3; versiones 20.3 anteriores a 20.3R3-S1; versiones 20.4 anteriores a 20.4R3; versiones 21.1 anteriores a 21.1R3; versiones 21.2 anteriores a 21.2R2. • https://kb.juniper.net/JSA11277 • CWE-772: Missing Release of Resource after Effective Lifetime •
CVE-2022-22169 – Junos OS and Junos OS Evolved: OSPFv3 session might go into INIT state upon receipt of multiple crafted packets from a trusted neighbor device.
https://notcve.org/view.php?id=CVE-2022-22169
An Improper Initialization vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an attacker who sends specific packets in certain orders and at specific timings to force OSPFv3 to unexpectedly enter graceful-restart (GR helper mode) even though there is not any Grace-LSA received in OSPFv3 causing a Denial of Service (DoS). Unexpectedly entering GR helper mode might cause the OSPFv3 neighbor adjacency formed on this interface to be stuck in the "INIT" state which can be observed by issuing the following command: user@device> show ospf3 neighbor ID Interface State xx.xx.xx.xx ae100.0 Init <<<<<<<<<< An indicator of compromise can be seen in log files when traceoptions for OSPFv3 are enabled before the issue occurs. These logfile messages are as follows: OSPF restart signaling: Received hello with LR bit set from nbr ip=xx::xx id=xx.xx.xx.xx. Set oob-resync capabilty 1. OSPF Restart Signaling: Start helper mode for nbr ip xx::xx id xx.xx.xx.xx OSPF restart signaling: abort helper mode for nbr ip=xx::xx id=xx.xx.xx.xx OSPF neighbor xx::xx (realm ipv6-unicast <interface.unit> area xx.xx.xx.xx) state changed from Full to Init due to 1WayRcvd (event reason: neighbor is in one-way mode) (nbr helped: 0) This issue affects: Juniper Networks Junos OS. 15.1 versions prior to 15.1R7-S11; 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S7, 19.2R3-S4; 19.3 versions prior to 19.3R2-S7, 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. • https://kb.juniper.net/JSA11276 • CWE-665: Improper Initialization •
CVE-2022-22168 – Junos OS: vMX and MX150: Specific packets might cause a memory leak and eventually an FPC reboot
https://notcve.org/view.php?id=CVE-2022-22168
An Improper Validation of Specified Type of Input vulnerability in the kernel of Juniper Networks Junos OS allows an unauthenticated adjacent attacker to trigger a Missing Release of Memory after Effective Lifetime vulnerability. Continued exploitation of this vulnerability will eventually lead to an FPC reboot and thereby a Denial of Service (DoS). This issue affects: Juniper Networks Junos OS on vMX and MX150: All versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. Una vulnerabilidad de Comprobación Inapropiada del Tipo de Entrada especificado en el kernel del Sistema Operativo Junos de Juniper Networks permite a un atacante adyacente no autenticado desencadenar una vulnerabilidad de Falta de Liberación de Memoria Después del Tiempo de Vida Efectivo. Una explotación continuada de esta vulnerabilidad conllevará finalmente a un reinicio del FPC y, por tanto, una denegación de servicio (DoS). • https://kb.juniper.net/JSA11275 • CWE-401: Missing Release of Memory after Effective Lifetime CWE-1287: Improper Validation of Specified Type of Input •