CVE-2021-3986 – Information Disclosure in janeczku/calibre-web
https://notcve.org/view.php?id=CVE-2021-3986
A vulnerability in janeczku/calibre-web allows unauthorized users to view the names of private shelves belonging to other users. This issue occurs in the file shelf.py at line 221, where the name of the shelf is exposed in an error message when a user attempts to remove a book from a shelf they do not own. This vulnerability discloses private information and affects all versions prior to the fix. Una vulnerabilidad en janeczku/calibre-web permite a usuarios no autorizados ver los nombres de los estantes privados que pertenecen a otros usuarios. Este problema se produce en el archivo shelf.py en la línea 221, donde el nombre del estante se expone en un mensaje de error cuando un usuario intenta eliminar un libro de un estante que no es de su propiedad. • https://github.com/janeczku/calibre-web/commit/6f5390ead5df9779ac81fadefffb476e03f93548 https://huntr.com/bounties/394af194-61a7-4e33-b373-877d4c766fca • CWE-209: Generation of Error Message Containing Sensitive Information •
CVE-2024-46383
https://notcve.org/view.php?id=CVE-2024-46383
Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. • http://skyworth.com https://github.com/nitinronge91/Sensitive-Information-disclosure-via-SPI-flash-firmware-for-Hathway-router-CVE-2024-46383 • CWE-312: Cleartext Storage of Sensitive Information •
CVE-2017-13227
https://notcve.org/view.php?id=CVE-2017-13227
This could lead to information disclosure with no additional execution privileges needed. • https://source.android.com/security/bulletin/2018-06-01 •
CVE-2024-48970 – Life2000 Ventilator microcontroller lacks memory protection
https://notcve.org/view.php?id=CVE-2024-48970
An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure. • https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01 • CWE-1191: On-Chip Debug and Test Interface With Improper Access Control •
CVE-2024-48974 – Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates
https://notcve.org/view.php?id=CVE-2024-48974
This could disrupt the function of the device and/or cause unauthorized information disclosure. • https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-319-01 • CWE-494: Download of Code Without Integrity Check •