CVSS: 5.4EPSS: 0%CPEs: 3EXPL: 0

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. Varias vulnerabilidades en la interfaz de administración basada en la web del software Cisco Firepower Management Center (FMC) podrían permitir a un atacante remoto autenticado conducir un ataque de tipo cross-site scripting (XSS) contra un usuario de la interfaz. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xss-qXz4uAkM • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 3EXPL: 0

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting attack. This vulnerability is due to improper validation of user-supplied input to the web-based management interface. An attacker could exploit this vulnerability by convincing a user to click a link designed to pass malicious input to the interface. A successful exploit could allow the attacker to conduct cross-site scripting attacks and gain access to sensitive browser-based information. Una vulnerabilidad en la interfaz de administración basada en la web del software Cisco Firepower Management Center (FMC) podría permitir a un atacante remoto no autenticado realizar un ataque de tipo cross-site scripting. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xss-SfpEcvGT • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •

CVSS: 9.0EPSS: 0%CPEs: 4EXPL: 0

A vulnerability in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to bypass security protections and upload malicious files to the affected system. This vulnerability is due to improper validation of files uploaded to the web management interface of Cisco FMC Software. An attacker could exploit this vulnerability by uploading a maliciously crafted file to a device running affected software. A successful exploit could allow the attacker to store malicious files on the device, which they could access later to conduct additional attacks, including executing arbitrary code on the affected device with root privileges. Una vulnerabilidad en la interfaz de administración web del software Cisco Firepower Management Center (FMC) podría permitir a un atacante remoto autenticado omitir las protecciones de seguridad y cargar archivos maliciosos en el sistema afectado. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-security-bypass-JhOd29Gg • CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 4.3EPSS: 0%CPEs: 3EXPL: 0

A vulnerability in an access control mechanism of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to access services beyond the scope of their authorization. This vulnerability is due to insufficient enforcement of access control in the affected software. An attacker could exploit this vulnerability by directly accessing the internal services of an affected device. A successful exploit could allow the attacker to overwrite policies and impact the configuration and operation of the affected device. Una vulnerabilidad en un mecanismo de control de acceso del software Cisco Firepower Management Center (FMC), podría permitir a un atacante remoto autenticado acceder a servicios más allá del alcance de su autorización. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-iac-pZDMQ4wC • CWE-284: Improper Access Control •

CVSS: 4.8EPSS: 0%CPEs: 3EXPL: 0

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. Múltiples vulnerabilidades en la interfaz de administración basada en web del software Cisco Firepower Management Center (FMC), podrían permitir a un atacante remoto no autenticado conducir un ataque de tipo cross-site scripting (XSS) contra un usuario de la interfaz. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xss-yT8LNSeA • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •