Page 7 of 38 results (0.014 seconds)

CVSS: 6.5EPSS: 0%CPEs: 897EXPL: 0

Cleanup errors in some data cache evictions for some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Unos errores de limpieza en algunos desalojos de caché de datos para algunos procesadores Intel(R), pueden permitir a un usuario autenticado habilitar potencialmente una divulgación de información por medio del acceso local. A microarchitectural timing flaw was found on some Intel processors. A corner case exists where data in-flight during the eviction process can end up in the “fill buffers” and not properly cleared by the MDS mitigations. The fill buffer contents (which were expected to be blank) can be inferred using MDS or TAA style attack methods to allow a local attacker to infer fill buffer values. • http://lists.opensuse.org/opensuse-security-announce/2020-06/msg00016.html https://kc.mcafee.com/corporate/index?page=content&id=SB10318 https://lists.debian.org/debian-lts-announce/2020/06/msg00019.html https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/DT2VKDMQ3I37NBNJ256A2EXR7OJHXXKZ https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/T5OUM24ZC43G4IDT3JUCIHJTSDXJSK6Y https://security.netapp.com/advisory/ntap-20200210-0004 https://usn.ubunt • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-404: Improper Resource Shutdown or Release •

CVSS: 5.5EPSS: 0%CPEs: 886EXPL: 0

Cleanup errors in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Unos errores de limpieza en algunos procesadores Intel(R), pueden permitir a un usuario autenticado habilitar potencialmente una divulgación de información por medio del acceso local. A flaw was found in Intel processors where a local attacker is able to gain information about registers used for vector calculations by observing register states from other processes running on the system. This results in a race condition where store buffers, which were not cleared, could be read by another process or a CPU sibling. The highest threat from this vulnerability is data confidentiality where an attacker could read arbitrary data as it passes through the processor. • http://lists.opensuse.org/opensuse-security-announce/2020-06/msg00016.html https://lists.debian.org/debian-lts-announce/2020/06/msg00019.html https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/DT2VKDMQ3I37NBNJ256A2EXR7OJHXXKZ https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/T5OUM24ZC43G4IDT3JUCIHJTSDXJSK6Y https://security.netapp.com/advisory/ntap-20200210-0004 https://usn.ubuntu.com/4385-1 https://www.debian.org/security/2020/dsa-47 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-404: Improper Resource Shutdown or Release •

CVSS: 5.5EPSS: 0%CPEs: 1040EXPL: 0

Insufficient control flow in certain data structures for some Intel(R) Processors with Intel(R) Processor Graphics may allow an unauthenticated user to potentially enable information disclosure via local access. El flujo de control insuficiente en determinadas estructuras de datos para algunos Procesadores de Intel(R) con Intel(R) Processor Graphics, puede permitir a un usuario no autenticado habilitar potencialmente una divulgación de información por medio de un acceso local. An information disclosure flaw was found in the Linux kernel. The i915 graphics driver lacks control of flow for data structures which may allow a local, authenticated user to disclose information when using ioctl commands with an attached i915 device. The highest threat from this vulnerability is to data confidentiality. • http://lists.opensuse.org/opensuse-security-announce/2020-03/msg00021.html http://packetstormsecurity.com/files/156185/Kernel-Live-Patch-Security-Notice-LSN-0062-1.html http://packetstormsecurity.com/files/156455/Kernel-Live-Patch-Security-Notice-LSN-0063-1.html http://seclists.org/fulldisclosure/2020/Mar/31 https://lists.debian.org/debian-lts-announce/2020/03/msg00001.html https://support.apple.com/kb/HT211100 https://usn.ubuntu.com/4253-1 https://usn.ubuntu.com/4253-2 https://us • CWE-212: Improper Removal of Sensitive Information Before Storage or Transfer •

CVSS: 6.7EPSS: 0%CPEs: 664EXPL: 0

Improper conditions check in voltage settings for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege and/or information disclosure via local access. Una comprobación de condiciones inapropiadas en la configuración de voltaje para algunos procesadores Intel(R) pueden permitir que un usuario con privilegios pueda permitir la escalada de privilegios y/o la divulgación de información a través del acceso local. • https://security.netapp.com/advisory/ntap-20191217-0001 https://support.f5.com/csp/article/K10321239?utm_source=f5support&amp%3Butm_medium=RSS https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00289.html •

CVSS: 5.3EPSS: 0%CPEs: 892EXPL: 0

Improper conditions check in multiple Intel® Processors may allow an authenticated user to potentially enable partial escalation of privilege, denial of service and/or information disclosure via local access. La verificación de condiciones inadecuadas en múltiples procesadores Intel® puede permitir a un usuario autenticado habilitar potencialmente la escalada parcial de privilegios, la denegación de servicio y / o la divulgación de información a través del acceso local. • https://security.netapp.com/advisory/ntap-20191217-0002 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00317.html https://www.synology.com/security/advisory/Synology_SA_19_42 • CWE-754: Improper Check for Unusual or Exceptional Conditions •