Page 7 of 47 results (0.013 seconds)

CVSS: 8.1EPSS: 0%CPEs: 6EXPL: 0

Incorrect access control in the RPC framework in Odoo Community 8.0 through 11.0 and Odoo Enterprise 9.0 through 11.0 allows authenticated users to call private functions via RPC. El control de acceso incorrecto en el marco de RPC en Odoo Community 8.0 a 11.0 y Odoo Enterprise 9.0 a 11.0 permite a los usuarios identificados llamar a funciones privadas a través de RPC. • https://github.com/odoo/odoo/issues/32508 • CWE-284: Improper Access Control •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

Incorrect access control in asset bundles in Odoo Community 9.0 through 11.0 and earlier and Odoo Enterprise 9.0 through 11.0 and earlier allows remote authenticated users to inject arbitrary web script via a crafted attachment. El control de acceso incorrecto en los paquetes de activos en Odoo Community 9.0 a 11.0 y anteriores y Odoo Enterprise 9.0 a 11.0 y anteriores permite a los usuarios identificados remotamente inyectar un script web arbitrario a través de un adjunto diseñado. • https://github.com/odoo/odoo/issues/32502 • CWE-284: Improper Access Control •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

Report engine in Odoo Community 9.0 through 11.0 and earlier and Odoo Enterprise 9.0 through 11.0 and earlier does not use secure options when passing documents to wkhtmltopdf, which allows remote attackers to read local files. El motor de informes en Odoo Community versión 9.0 hasta la versión 11.0 y versiones anteriores y Odoo Enterprise versión 9.0 hasta la versión 11.0 y versiones anteriores no usa opciones seguras al pasar documentos a wkhtmltopdf, lo que permite a los atacantes remotos leer archivos locales. • https://github.com/odoo/odoo/issues/32501 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 4.3EPSS: 0%CPEs: 6EXPL: 0

Incorrect access control in the TransientModel framework in Odoo Community 11.0 and earlier and Odoo Enterprise 11.0 and earlier allows authenticated attackers to access data in transient records that they do not own by making an RPC call before garbage collection occurs. El control de acceso incorrecto en el marco de TransientModel en Odoo Community 11.0 y versiones anteriores y Odoo Enterprise 11.0 y versiones anteriores permite que los atacantes identificados accedan a datos en registros transitorios que no poseen al realizar una llamada RPC antes de que se produzca la recolección de basura. • https://github.com/odoo/odoo/issues/32509 • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 5.3EPSS: 0%CPEs: 4EXPL: 0

Incorrect access control in the portal messaging system in Odoo Community 9.0 and 10.0 and Odoo Enterprise 9.0 and 10.0 allows remote attackers to post messages on behalf of customers, and to guess document attribute values, via crafted parameters. El control de acceso incorrecto en el sistema de mensajería del portal en Odoo Community versiones 9.0 y 10.0 y Odoo Enterprise versiones 9.0 y 10.0 permite a los atacantes remotos publicar mensajes en nombre de los clientes y adivinar los valores de los atributos de los documentos, a través de parámetros diseñados. • https://github.com/odoo/odoo/commits/master https://github.com/odoo/odoo/issues/32503 • CWE-284: Improper Access Control •