CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A Use After Free Vulnerability exists in the Open Design Alliance Drawings SDK before 2022.11. The specific flaw exists within the parsing of DWF files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Se presenta una vulnerabilidad de uso de memoria previamente liberada en Open Design Alliance Drawings SDK versiones anteriores a 2022.11. • https://www.opendesign.com/security-advisories • CWE-416: Use After Free •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A Use After Free vulnerability exists in the DGN file reading procedure in Open Design Alliance Drawings SDK before 2022.8. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Se presenta una vulnerabilidad de Uso de Memoria previamente Liberada en el procedimiento de lectura de archivos DGN en Open Design Alliance Drawings SDK versiones anteriores a 2022.8. El problema es debido a que no se comprueba la existencia de un objeto antes de llevar a cabo operaciones con él. • https://www.opendesign.com/security-advisories • CWE-416: Use After Free •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

A use-after-free issue exists in the DGN file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process. Se presenta un problema de uso de la memoria previamente liberada en el procedimiento de lectura de archivos DGN en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una corrupción de memoria o en una ejecución de código arbitrario, permitiendo a atacantes causar una condición de denegación de servicio o ejecutar código en el contexto del proceso actual This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-987 https://www.zerodayinitiative.com/advisories/ZDI-21-990 • CWE-416: Use After Free •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

An out-of-bounds read issue exists within the parsing of DXF files in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations. Se presenta un problema de lectura fuera de límites en el análisis de archivos DXF en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una lectura más allá del final de un búfer asignado y permite a atacantes causar una condición de denegación de servicio o leer información confidencial de las ubicaciones de memoria This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DXF files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-988 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. Se presenta un problema de escritura fuera de límites en el procedimiento de lectura de archivos DGN en Drawings SDK (versión 2022.4 y anteriores) resultando de una falta de comprobación apropiada de los datos suministrados por el usuario. Esto puede resultar en una escritura más allá del final de un búfer asignado y permitir a atacantes causar una condición de denegación de servicio o ejecutar código en el contexto del proceso actual This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DGN files. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 https://www.zerodayinitiative.com/advisories/ZDI-21-989 • CWE-787: Out-of-bounds Write •