Page 7 of 38 results (0.054 seconds)

CVSS: 9.8EPSS: 0%CPEs: 120EXPL: 0

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. Existen algoritmos de hash vulnerables en los controladores Modicon Premium, Modicon Quantum, Modicon M340 y BMXNOR0200, de Schneider Electric, en todas las versiones de los módulos de comunicación. El algoritmo empleado para cifrar la contraseña es vulnerable a ataques de colisión de hash. • http://www.securityfocus.com/bid/103543 https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01 • CWE-326: Inadequate Encryption Strength •

CVSS: 9.8EPSS: 0%CPEs: 120EXPL: 0

An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. Existe una vulnerabilidad de omisión de autenticación en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric. Las peticiones a funciones CGI permiten que usuarios maliciosos omitan la autorización. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-287: Improper Authentication •

CVSS: 9.8EPSS: 0%CPEs: 120EXPL: 0

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. Existe una vulnerabilidad en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric, que podría permitir la ejecución de código arbitrario. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 120EXPL: 0

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. Existe una vulnerabilidad de desbordamiento de búfer en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric. La vulnerabilidad de desbordamiento de búfer se provoca por el tamaño de la cadena de origen especificada (en lugar del tamaño del búfer) como número de bytes que deben copiarse. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.8EPSS: 0%CPEs: 30EXPL: 0

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. Se ha descubierto un problema de agotamiento de recursos en Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H y BMXP342030H. Un atacante remoto podría enviar un conjunto de paquetes manipulados al PLC para congelarlo, lo que requeriría que el operador presionase físicamente el botón reset en el PLC para recuperarlo. • http://www.securityfocus.com/bid/96414 https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02 • CWE-400: Uncontrolled Resource Consumption •