CVE-2025-30031
https://notcve.org/view.php?id=CVE-2025-30031
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version o... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-30030
https://notcve.org/view.php?id=CVE-2025-30030
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable versio... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-30003
https://notcve.org/view.php?id=CVE-2025-30003
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnera... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-30002
https://notcve.org/view.php?id=CVE-2025-30002
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulner... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-29905
https://notcve.org/view.php?id=CVE-2025-29905
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable ver... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-27540
https://notcve.org/view.php?id=CVE-2025-27540
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable versio... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-27539
https://notcve.org/view.php?id=CVE-2025-27539
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version ... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2025-27495
https://notcve.org/view.php?id=CVE-2025-27495
16 Apr 2025 — A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version... • https://cert-portal.siemens.com/productcert/html/ssa-443402.html • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2024-44102
https://notcve.org/view.php?id=CVE-2024-44102
12 Nov 2024 — A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured... • https://cert-portal.siemens.com/productcert/html/ssa-454789.html • CWE-502: Deserialization of Untrusted Data •

CVE-2021-45117
https://notcve.org/view.php?id=CVE-2021-45117
21 Mar 2022 — The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference. Los stubs de pila ANSI C autogenerados por OPC (en los NodeSets) no manejan todos los casos de error. Esto puede conllevar a una desreferencia de puntero NULL • https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf • CWE-476: NULL Pointer Dereference •