CVE-2022-45644
https://notcve.org/view.php?id=CVE-2022-45644
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function. Se descubrió que Tenda AC6V1.0 V15.03.05.19 contenía un desbordamiento del búfer a través del parámetro deviceId en la función formSetClientState. • https://github.com/Double-q1015/CVE-vulns/blob/main/tenda_ac6/formSetClientState_deviceId/formSetClientState_deviceId.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2022-45654
https://notcve.org/view.php?id=CVE-2022-45654
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function. Se descubrió que Tenda AC6V1.0 V15.03.05.19 contenía un desbordamiento de búfer a través del parámetro ssid en la función form_fast_setting_wifi_set. • https://github.com/Double-q1015/CVE-vulns/blob/main/tenda_ac6/form_fast_setting_wifi_set_ssid/form_fast_setting_wifi_set_ssid.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2022-45659
https://notcve.org/view.php?id=CVE-2022-45659
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Se descubrió que Tenda AC6V1.0 V15.03.05.19 contenía un desbordamiento de búfer a través del parámetro wpapsk_crypto en la función fromSetWirelessRepeat. • https://github.com/Double-q1015/CVE-vulns/blob/main/tenda_ac6/fromSetWirelessRepeat/fromSetWirelessRepeat.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2022-45653
https://notcve.org/view.php?id=CVE-2022-45653
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function. Se descubrió que Tenda AC6V1.0 V15.03.05.19 contenía un desbordamiento de búfer a través del parámetro de página en la función fromNatStaticSetting. • https://github.com/Double-q1015/CVE-vulns/blob/main/tenda_ac6/fromNatStaticSetting/fromNatStaticSetting_page.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2022-45661
https://notcve.org/view.php?id=CVE-2022-45661
Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function. Se descubrió que Tenda AC6V1.0 V15.03.05.19 contenía un desbordamiento de búfer a través del parámetro de tiempo en la función setSmartPowerManagement. • https://github.com/Double-q1015/CVE-vulns/blob/main/tenda_ac6/setSmartPowerManagement/setSmartPowerManagement.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •