CVSS: 5.5EPSS: 0%CPEs: 131EXPL: 0

An Out-of-bounds Read vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX Series allows a local, authenticated attacker with low privileges, to cause a Denial of Service (DoS). If a low privileged user executes a specific CLI command, flowd which is responsible for traffic forwarding in SRX crashes and generates a core dump. This will cause temporary traffic interruption until the flowd process is restarted automatically. Continued execution of this command will lead to a sustained DoS. This issue affects Juniper Networks Junos OS on SRX Series: All versions prior to 20.2R3-S7; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3-S6; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S4; 21.4 versions prior to 21.4R3-S3; 22.1 versions prior to 22.1R3-S1; 22.2 versions prior to 22.2R3; 22.3 versions prior to 22.3R2; 22.4 versions prior to 22.4R1-S1, 22.4R2. • https://supportportal.juniper.net/JSA71645 • CWE-125: Out-of-bounds Read •

CVSS: 7.5EPSS: 0%CPEs: 198EXPL: 0

An Improper Handling of Exceptional Conditions vulnerability in packet processing of Juniper Networks Junos OS on MX Series allows an unauthenticated network-based attacker to send specific packets to an Aggregated Multiservices (AMS) interface on the device, causing the packet forwarding engine (PFE) to crash, resulting in a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue is only triggered by packets destined to a local-interface via a service-interface (AMS). AMS is only supported on the MS-MPC, MS-MIC, and MX-SPC3 cards. This issue is not experienced on other types of interfaces or configurations. Additionally, transit traffic does not trigger this issue. This issue affects Juniper Networks Junos OS on MX Series: All versions prior to 19.1R3-S10; 19.2 versions prior to 19.2R3-S7; 19.3 versions prior to 19.3R3-S8; 19.4 versions prior to 19.4R3-S12; 20.2 versions prior to 20.2R3-S8; 20.4 versions prior to 20.4R3-S7; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S5; 21.3 versions prior to 21.3R3-S4; 21.4 versions prior to 21.4R3-S3; 22.1 versions prior to 22.1R3-S2; 22.2 versions prior to 22.2R3; 22.3 versions prior to 22.3R2-S1, 22.3R3; 22.4 versions prior to 22.4R1-S2, 22.4R2. • https://supportportal.juniper.net/JSA71639 • CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 4.7EPSS: 0%CPEs: 118EXPL: 0

An Improper Check for Unusual or Exceptional Conditions vulnerability in the kernel of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to bypass an integrity check. In a 6PE scenario and if an additional integrity check is configured, it will fail to drop specific malformed IPv6 packets, and then these packets will be forwarded to other connected networks. This issue affects Juniper Networks Junos OS: All versions prior to 19.3R3-S7; 19.4 versions prior to 19.4R3-S9; 20.2 versions prior to 20.2R3-S7; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S2; 21.3 versions prior to 21.3R3-S1; 21.4 versions prior to 21.4R2-S1, 21.4R3; 22.1 versions prior to 22.1R2; 22.2 versions prior to 22.2R2. • https://supportportal.juniper.net/JSA70604 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 6.5EPSS: 0%CPEs: 122EXPL: 0

An Improper Check or Handling of Exceptional Conditions vulnerability in packet processing of Juniper Networks Junos OS on QFX10002 allows an unauthenticated, adjacent attacker on the local broadcast domain sending a malformed packet to the device, causing all PFEs other than the inbound PFE to wedge and to eventually restart, resulting in a Denial of Service (DoS) condition. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue can only be triggered by sending a specific malformed packet to the device. Transit traffic does not trigger this issue. An indication of this issue occurring can be seen through the following log messages: fpc0 expr_hostbound_packet_handler: Receive pe 73? • https://supportportal.juniper.net/JSA70584 • CWE-703: Improper Check or Handling of Exceptional Conditions •

CVSS: 5.8EPSS: 0%CPEs: 83EXPL: 0

An Improper Handling of Unexpected Data Type vulnerability in IPv6 firewall filter processing of Juniper Networks Junos OS on the ACX Series devices will prevent a firewall filter with the term 'from next-header ah' from being properly installed in the packet forwarding engine (PFE). There is no immediate indication of an incomplete firewall filter commit shown at the CLI, which could allow an attacker to send valid packets to or through the device that were explicitly intended to be dropped. An indication that the filter was not installed can be identified with the following logs: fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_rule_prepare : Config failed: Unsupported Ip-protocol 51 in the filter lo0.0-inet6-i fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_rule_prepare : Please detach the filter, remove unsupported match and re-attach fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_process_rule : Status:104 dnx_dfw_rule_prepare failed fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_process_filter : Status:104 dnx_dfw_process_rule failed fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_update_filter_in_hw : Status:104 Could not process filter(lo0.0-inet6-i) for rule expansion Unsupported match, action present. fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_create_hw_instance : Status:104 Could not program dfw(lo0.0-inet6-i) type(IFP_DFLT_INET6_Lo0_FILTER)! [104] fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_bind_shim : [104] Could not create dfw(lo0.0-inet6-i) type(IFP_DFLT_INET6_Lo0_FILTER) fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_update_resolve : [100] Failed to bind filter(3) to bind point fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_change_end : dnx_dfw_update_resolve (resolve type) failed This issue affects Juniper Networks Junos OS on ACX Series: All versions prior to 20.2R3-S7; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R3; 22.1 versions prior to 22.1R2. • https://supportportal.juniper.net/JSA70586 • CWE-241: Improper Handling of Unexpected Data Type •