Page 8 of 42 results (0.007 seconds)

CVSS: 7.5EPSS: 0%CPEs: 6EXPL: 1

The WBM web application on firmwares prior to 03.02.02 and 03.01.07 on the WAGO PFC100 and PFC2000, respectively, runs on a lighttpd web server and makes use of the FastCGI module, which is intended to provide high performance for all Internet applications without the penalties of Web server APIs. However, the default configuration of this module appears to limit the number of concurrent php-cgi processes to two, which can be abused to cause a denial of service of the entire web server. This affects WAGO PFC200 Firmware version 03.00.39(12) and version 03.01.07(13), and WAGO PFC100 Firmware version 03.00.39(12) and version 03.02.02(14). La aplicación web WBM en WAGO PFC100 y PFC2000, versiones de firmware anteriores a las versiones 03.02.02 y 03.01.07 respectivamente, se ejecuta en un servidor web lighttpd y hace uso del módulo FastCGI, que está destinado a proporcionar un alto rendimiento para todas las aplicaciones de Internet sin las penalizaciones de las API del servidor web. Sin embargo, la configuración predeterminada de este módulo parece limitar el número de procesos concurrentes de php-cgi a dos, lo cual puede ser violado para causar una denegación de servicio de todo el servidor web. • https://talosintelligence.com/vulnerability_reports/TALOS-2019-0939 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 9.0EPSS: 0%CPEs: 4EXPL: 1

An exploitable command injection vulnerability exists in the cloud connectivity feature of WAGO PFC200. An attacker can inject operating system commands into any of the parameter values contained in the firmware update command. This affects WAGO PFC200 Firmware version 03.02.02(14), version 03.01.07(13), and version 03.00.39(12) Existe una vulnerabilidad de inyección de comando explotable en la funcionalidad cloud connectivity de WAGO PFC200. Un atacante puede inyectar comandos de sistema operativo en cualquiera de los valores de parámetros contenidos en el comando de actualización de firmware. Esto afecta a la versión de firmware WAGO PFC200 03.02.02(14), la versión 03.01.07(13) y la versión 03.00.39(12) • https://talosintelligence.com/vulnerability_reports/TALOS-2019-0948 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 9.8EPSS: 21%CPEs: 11EXPL: 4

eap.c in pppd in ppp 2.4.2 through 2.4.8 has an rhostname buffer overflow in the eap_request and eap_response functions. El archivo eap.c en pppd en ppp versiones 2.4.2 hasta 2.4.8, presenta un desbordamiento del búfer de rhostname en las funciones eap_request y eap_response. A buffer overflow flaw was found in the ppp package in versions 2.4.2 through 2.4.8. The bounds check for the rhostname was improperly constructed in the EAP request and response functions which could allow a buffer overflow to occur. Data confidentiality and integrity, as well as system availability, are all at risk with this vulnerability. • https://github.com/dointisme/CVE-2020-8597 https://github.com/WinMin/CVE-2020-8597 https://github.com/lakwsh/CVE-2020-8597 https://github.com/Dilan-Diaz/Point-to-Point-Protocol-Daemon-RCE-Vulnerability-CVE-2020-8597- http://lists.opensuse.org/opensuse-security-announce/2020-03/msg00006.html http://packetstormsecurity.com/files/156662/pppd-2.4.8-Buffer-Overflow.html http://packetstormsecurity.com/files/156802/pppd-2.4.8-Buffer-Overflow.html http://seclists.org/fulldisclosure/2020/Mar/ • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 9.8EPSS: 0%CPEs: 5EXPL: 1

An exploitable heap buffer overflow vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause a heap buffer overflow, potentially resulting in code execution. An attacker can send unauthenticated packets to trigger this vulnerability. Existe una vulnerabilidad de desbordamiento del búfer de la pila explotable en la funcionalidad I-O-Check del servicio iocheckd de WAGO PFC200 Firmware versión 03.01.07(13), WAGO PFC200 Firmware versión 03.00.39(12) y WAGO PFC100 Firmware versión 03.00.39(12 ). Un conjunto de paquetes especialmente diseñado puede causar un desbordamiento del búfer de la pila, resultando potencialmente en una ejecución de código. • https://talosintelligence.com/vulnerability_reports/TALOS-2019-0874 • CWE-787: Out-of-bounds Write •

CVSS: 5.8EPSS: 0%CPEs: 3EXPL: 0

Information Disclosure is possible on WAGO Series PFC100 and PFC200 devices before FW12 due to improper access control. A remote attacker can check for the existence of paths and file names via crafted HTTP requests. Una divulgación de información es posible en los dispositivos WAGO Series PFC100 y PFC200 versiones anteriores a FW12, debido a un control de acceso inapropiado. Un atacante remoto puede comprobar la existencia de rutas y nombres de archivos por medio de peticiones HTTP diseñadas. • https://cert.vde.com/de-de/advisories/vde-2019-017 •