Page 80 of 490 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 25EXPL: 0

Juniper Networks QFX3500, QFX3600, QFX5100, QFX5200, EX4300 and EX4600 devices running Junos OS 14.1X53 prior to 14.1X53-D40, 15.1X53 prior to 15.1X53-D40, 15.1 prior to 15.1R2, do not pad Ethernet packets with zeros, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak' Los dispositivos QFX3500, QFX3600, QFX5100, QFX5200, EX4300 y EX4600 de Juniper Networks que ejecutan Junos OS 14.1X53 anteriores a 14.1X53-D40, 15.1X53 anteriores a 15.1X53-D40 y 15.1 anteriores a 15.1R2, no rellenan paquetes Ethernet con ceros por lo que algunos paquetes pueden contener fragmentos de memoria del sistema o datos de paquetes anteriores. Este problema también es conocido como "Etherleak" • http://www.securityfocus.com/bid/95403 http://www.securitytracker.com/id/1037593 https://kb.juniper.net/JSA10773 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 7.5EPSS: 0%CPEs: 3EXPL: 0

On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets. En los clústeres de tipo chassis de dispositivos Juniper Networks SRX Series Services Gateways que ejecutan el sistema operativo versiones: Junos 12.1X46 anterior a 12.1X46-D65, 12.3X48 anterior a 12.3X48-D40 y12.3X48 anterior a 12.3X48-D60, el demonio flowd en el nodo principal del clúster, puede bloquearse y reiniciarse al intentar sincronizar una sesión multicast creada mediante paquetes multicast especialmente diseñados. • http://www.securityfocus.com/bid/95400 http://www.securitytracker.com/id/1037597 https://kb.juniper.net/JSA10768 •

CVSS: 7.8EPSS: 0%CPEs: 71EXPL: 0

On Juniper Networks products or platforms running Junos OS 12.1X46 prior to 12.1X46-D55, 12.1X47 prior to 12.1X47-D45, 12.3R13 prior to 12.3R13, 12.3X48 prior to 12.3X48-D35, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D40, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R6, 15.1 prior to 15.1F2 or 15.1R1, 15.1X49 prior to 15.1X49-D20 where the BGP add-path feature is enabled with 'send' option or with both 'send' and 'receive' options, a network based attacker can cause the Junos OS rpd daemon to crash and restart. Repeated crashes of the rpd daemon can result in an extended denial of service condition. En productos o plataformas Juniper Networks que ejecutan Junos OS 12.1X46 anteriores a 12.1X46-D55, 12.1X47 anteriores a 12.1X47-D45, 12.3R13 anteriores a 12.3R13, 12.3X48 anteriores a 12.3X48-D35, 13.3 anteriores a 13.3R10, 14.1 anteriores a 14.1R8, 14.1X53 anteriores a 14.1X53-D40, 14.1X55 anteriores a 14.1X55-D35, 14.2 anteriores a 14.2R6, 15.1 anteriores a 15.1F2 oO 15.1R1, 15.1X49 anteriores a 15.1X49-D20, donde la funcionalidad BGP add-path está habilitada con la opción 'send' o con las opciones 'enviar' y 'recibir', un atacante en la red puede causar que el demonio rpd de Junos OS se bloquee y se reinicie. Los repetidos bloqueos del demonio rpd pueden resultar en una condición extendida de denegación de servicio. • http://www.securityfocus.com/bid/95394 http://www.securitytracker.com/id/1037595 https://kb.juniper.net/JSA10771 •

CVSS: 7.8EPSS: 0%CPEs: 103EXPL: 0

On Juniper Networks products or platforms running Junos OS 11.4 prior to 11.4R13-S3, 12.1X46 prior to 12.1X46-D60, 12.3 prior to 12.3R12-S2 or 12.3R13, 12.3X48 prior to 12.3X48-D40, 13.2X51 prior to 13.2X51-D40, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D12 or 14.1X53-D35, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R7, 15.1 prior to 15.1F6 or 15.1R3, 15.1X49 prior to 15.1X49-D60, 15.1X53 prior to 15.1X53-D30 and DHCPv6 enabled, when a crafted DHCPv6 packet is received from a subscriber, jdhcpd daemon crashes and restarts. Repeated crashes of the jdhcpd process may constitute an extended denial of service condition for subscribers attempting to obtain IPv6 addresses. En los productos o plataformas Juniper Networks que ejecutan Junos OS versiones 11.4 anteriores a 11.4R13-S3, 12.1X46 anteriores a 12.1X46-D60, 12.3 anteriores a 12.3R12-S2 o 12.3R13, 12.3X48 anteriores a 12.3X48-D40, 13.2X51 anteriores a 13.2X51-D40, 13.3 anteriores a 13.3R10, 14.1 anteriores a 14.1R8, 14.1X53 anteriores a 14.1X53-D12 o 14.1X53-D35, 14.1X55 anteriores a 14.1X55-D35, 14.2 anteriores a 14.2R7, 15.1 anteriores a 15.1F6 o 15.1R3, 15.1X49 anteriores a 15.1X49-D60, 15.1X53 anteriores a 15.1X53-D30 y además tiene habilitado DHCPv6, cuando un paquete DHCPv6 especialmente diseñado es recibido desde un suscriptor, el demonio jdhcpd se bloquea y se reinicia. Los bloqueos repetidos del proceso jdhcpd pueden constituir una condición extendida de denegación de servicio para los suscriptores que intentan obtener direcciones IPv6. • http://www.securityfocus.com/bid/95396 http://www.securitytracker.com/id/1037596 https://kb.juniper.net/JSA10769 •

CVSS: 7.8EPSS: 0%CPEs: 47EXPL: 0

On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability. En Switches EX Series Ethernet de Juniper Networks ejecutando las versiones afectadas del Junos OS, se detectó una vulnerabilidad en el procesamiento IPv6 que puede permitir que un paquete Neighbor Discovery (ND) de IPv6 especialmente diseñado destinado hacia un Switch EX Series Ethernet cause una pérdida de memoria lenta. Una inundación de paquetes maliciosos sobre la red de estos paquetes NDP de IPv6 diseñados puede eventualmente conllevar al agotamiento de recursos y a una denegación de servicio. • http://www.securityfocus.com/bid/97615 http://www.securitytracker.com/id/1038253 https://kb.juniper.net/JSA10781 • CWE-772: Missing Release of Resource after Effective Lifetime •