Page 85 of 557 results (0.016 seconds)

CVSS: 10.0EPSS: 0%CPEs: 22EXPL: 0

The vMX Series software uses a predictable IP ID Sequence Number. This leaves the system as well as clients connecting through the device susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F5 on vMX Series. El software de la serie vMX emplea un número de secuencia IP ID predecible. • http://www.securityfocus.com/bid/106564 https://kb.juniper.net/JSA10903 • CWE-330: Use of Insufficiently Random Values •

CVSS: 7.5EPSS: 0%CPEs: 78EXPL: 0

An SRX Series Service Gateway configured for Unified Threat Management (UTM) may experience a system crash with the error message "mbuf exceed" -- an indication of memory buffer exhaustion -- due to the receipt of crafted HTTP traffic. Each crafted HTTP packet inspected by UTM consumes mbufs which can be identified through the following log messages: all_logs.0:Jun 8 03:25:03 srx1 node0.fpc4 : SPU3 jmpi mbuf stall 50%. all_logs.0:Jun 8 03:25:13 srx1 node0.fpc4 : SPU3 jmpi mbuf stall 51%. all_logs.0:Jun 8 03:25:24 srx1 node0.fpc4 : SPU3 jmpi mbuf stall 52%. ... Eventually the system runs out of mbufs and the system crashes (fails over) with the error "mbuf exceed". This issue only occurs when HTTP AV inspection is configured. Devices configured for Web Filtering alone are unaffected by this issue. • http://www.securityfocus.com/bid/106535 https://kb.juniper.net/JSA10910 • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 7.5EPSS: 0%CPEs: 103EXPL: 0

The routing protocol daemon (RPD) process will crash and restart when a specific invalid IPv4 PIM Join packet is received. While RPD restarts after a crash, repeated crashes can result in an extended Denial of Service (DoS) condition. This issue only affects IPv4 PIM. IPv6 PIM is unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77; 12.3X48 versions prior to 12.3X48-D77; 15.1 versions prior to 15.1F6-S10, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D150; 15.1X53 versions prior to 15.1X53-D233, 15.1X53-D59; 16.1 versions prior to 16.1R3-S8, 16.1R4-S8, 16.1R7; 16.2 versions prior to 16.2R2-S6; 17.1 versions prior to 17.1R2-S6, 17.1R3; 17.2 versions prior to 17.2R2-S3, 17.2R3; 17.3 versions prior to 17.3R2-S4, 17.3R3; 17.4 versions prior to 17.4R2. • http://www.securityfocus.com/bid/106519 https://kb.juniper.net/JSA10913 • CWE-19: Data Processing Errors •

CVSS: 5.5EPSS: 0%CPEs: 14EXPL: 0

On EX2300 and EX3400 series, high disk I/O operations may disrupt the communication between the routing engine (RE) and the packet forwarding engine (PFE). In a virtual chassis (VC) deployment, this issue disrupts communication between the VC members. This issue does not affect other Junos platforms. Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R2-S2, 18.1R3; 18.2 versions prior to 18.2R2. En las series EX2300 y EX3400, las operaciones high disk I/O podrían interrumpir las comunicaciones entre el motor de enrutamiento (RE) y el motor de reenvío de paquetes (PFE). • http://www.securityfocus.com/bid/106548 https://kb.juniper.net/JSA10909 •

CVSS: 9.8EPSS: 0%CPEs: 20EXPL: 0

On EX2300 and EX3400 series, stateless firewall filter configuration that uses the action 'policer' in combination with other actions might not take effect. When this issue occurs, the output of the command: show pfe filter hw summary will not show the entry for: RACL group Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. This issue affect both IPv4 and IPv6 firewall filter. En las series EX2300 y EX3400, la configuración sin estado del filtro del firewall que emplea la acción "policer" junto con otras acciones podría no aplicarse. Cuando este problema ocurre, el resultado del comando show pfe filter hw summary no mostrará la entrada para: RACL group. • http://www.securityfocus.com/bid/106669 https://kb.juniper.net/JSA10901 https://www.juniper.net/documentation/en_US/junos/topics/reference/command-summary/show-pfe-filter.html • CWE-794: Incomplete Filtering of Multiple Instances of Special Elements •