CVE-2019-6837
https://notcve.org/view.php?id=CVE-2019-6837
A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL. Una vulnerabilidad Server-Side Request Forgery (SSRF): Se presenta una vulnerabilidad CWE-918 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), lo que podría causar que datos de configuración del servidor sean expuestos cuando un atacante modifica una URL. • https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01 • CWE-918: Server-Side Request Forgery (SSRF) •
CVE-2019-6836
https://notcve.org/view.php?id=CVE-2019-6836
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file. Un Control de Acceso Incorrecto: Se presenta una vulnerabilidad CWE-863 en U.motion Server (MEG6501-0001 - U.motion KNX Server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), que podría permitir que el sistema de archivos acceda al archivo incorrecto • https://www.se.com/ww/en/download/document/SEVD-2019-253-01 • CWE-863: Incorrect Authorization •
CVE-2019-6835
https://notcve.org/view.php?id=CVE-2019-6835
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page. Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) CWE-79 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), que podría permitir a un atacante inyectar script del lado del cliente cuando un usuario visita una página web. • https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •
CVE-2018-7838
https://notcve.org/view.php?id=CVE-2018-7838
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service. Una CWE-119: Existe una vulnerabilidad de Errores de Búfer en la CPU M580 - BMEP582040 de Modicon , todas las versiones anteriores a la V2.90, y el módulo Ethernet BMENOC0301 de Modicon, todas las versiones anteriores a la V2.16, lo que podría causar la denegación de servicio en el servicio FTP del controlador o Módulo Ethernet BMENOC cuando recibe un comando CWD de FTP con una longitud de datos superior a 1020 bytes. Se necesita entonces un ciclo de energía para reactivar el servicio FTP. • https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2019-6827 – Schneider Electric IGSS MDB Database BaseUnits UnitIdx Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2019-6827
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. Una CWE-787: Existe una vulnerabilidad de escritura fuera de límites en Interactive Graphical SCADA System (IGSS), versión 14 y anteriores, que podría causar un bloqueo del software cuando son manipulados los datos en la base de datos mdb. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within use of the UnitIdx data in the BaseUnits table. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. • https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-02 https://www.zerodayinitiative.com/advisories/ZDI-19-671 • CWE-787: Out-of-bounds Write •