CVSS: 9.8EPSS: 0%CPEs: 10EXPL: 0

Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. Vulnerabilidad de uso de entrada controlada externamente para seleccionar clases o código ("Reflexión insegura") en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versión1(GOT1000) todas las versiones, GT Designer3 Versión1(GOT2000) todas las versiones , GX Works2 versiones 1.11M y posteriores, GX Works3 todas las versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten que un atacante remoto no autenticado ejecute un código malicioso por RPC con una ruta a una librería maliciosa mientras está conectado a los productos. Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. • https://jvn.jp/vu/JVNVU95103362 https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf • CWE-470: Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally. Autenticación faltante para vulnerabilidad de función crítica en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versión1(GOT1000) todas las versiones, GT Designer3 Versión1(GOT2000) todas las versiones, GX Works2 versiones 1.11M y posteriores, GX Works3 todas versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten a un atacante remoto no autenticado eludir la autenticación enviando paquetes especialmente manipulados y conectándose a los productos ilegalmente. Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally. • https://jvn.jp/vu/JVNVU95103362 https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.1EPSS: 0%CPEs: 3EXPL: 0

Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server. Una vulnerabilidad de lectura fuera de los límites en las versiones 10.97.1 y anteriores de ICONICS GENESIS64 y en las versiones 4.04E (10.95.210.01) y anteriores de Mitsubishi Electric MC Works64 permite a un atacante remoto no autenticado divulgar información en la memoria o causar una condición de denegación de servicio (DoS) mediante el envío de paquetes especialmente diseñados al servidor GENESIS64 This vulnerability allows remote attackers to disclose sensitive information on affected installations of ICONICS GENESIS64 GenBroker64. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GenBroker64 service, which listens on TCP port 38080 by default. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to disclose information in the context of the current process or to create a denial-of-service condition on the system. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-125: Out-of-bounds Read •

CVSS: 9.8EPSS: 0%CPEs: 3EXPL: 0

Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server. Una vulnerabilidad de Deserialización de Datos No Confiables en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante remoto no autenticado ejecutar un código malicioso arbitrario mediante el envío de paquetes especialmente diseñados al servidor GENESIS64 This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GenBroker64 service. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the Administrator. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. Una vulnerabilidad de Deserialización de Datos No Confiables en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de configuración de proyecto que incluye códigos XML maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PKGX files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-502: Deserialization of Untrusted Data •