Page 2 of 15 results (0.003 seconds)

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. Una vulnerabilidad de Deserialización de Datos No Confiables en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de pantalla de monitoreo que incluye códigos XAML maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TDFX files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. Una vulnerabilidad de Inclusión de Funcionalidad de la Esfera de Control No Confiable en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de pantalla de monitoreo que incluye códigos de script maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of GDFX files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the ICONICS_ADMIN user. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-829: Inclusion of Functionality from Untrusted Control Sphere •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. Una vulnerabilidad de Deserialización de Datos No Confiables en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de pantalla de monitoreo que incluye códigos XAML maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of GDFX files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-502: Deserialization of Untrusted Data •

CVSS: 9.8EPSS: 0%CPEs: 5EXPL: 0

Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products. Una vulnerabilidad "Incomplete List of Disallowed Inputs" en Mitsubishi Electric MC Works64 versiones 4.00A (10.95.201.23) a 4.04E (10.95.210.01), ICONICS GENESIS64 versiones 10.95.3 a 10.97, ICONICS Hyper Historian versiones 10.95.3 a 10.97, ICONICS AnalytiX versiones 10.95.3 a 10.97 e ICONICS MobileHMI versiones 10. 95.3 a 10.97 permite a un atacante remoto no autenticado omitir la autenticación de MC Works64, GENESIS64, Hyper Historian, AnalytiX y MobileHMI, y conseguir acceso no autorizado a los productos, mediante el envío de paquetes WebSocket especialmente diseñados al servidor FrameWorX, una de las funciones de los productos • https://jvn.jp/vu/JVNVU95403720/index.html https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf •

CVSS: 6.1EPSS: 0%CPEs: 2EXPL: 0

Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL. Una vulnerabilidad de tipo Cross-site Scripting en Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores, y en ICONICS MobileHMI versiones 10.96.2 y anteriores, permite a un atacante remoto no autenticado conseguir información de autenticación de un MC Works64 o MobileHMI y llevar a cabo cualquier operación usando la información de autenticación adquirida, inyectando un script malicioso en la URL de una pantalla de monitorización entregada desde el servidor MC Works64 o el servidor MobileHMI a una aplicación para dispositivos móviles y llevando a un usuario legítimo a acceder a esta URL • https://jvn.jp/vu/JVNVU95403720/index.html https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-025_en.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •