CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

This vulnerability allows local attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type-confusion condition in the Omron CX-One Version 4.60 and prior devices. Esta vulnerabilidad permite a atacantes locales ejecutar código arbitrario debido a una falta de comprobación apropiada de los datos suministrados por un usuario, lo que puede resultar en una condición de confusión de tipos en Omron CX-One Versión 4.60 y dispositivos anteriores This vulnerability allows remote attackers to execute arbitrary code on affected installations of Omron CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PSW files by the CX-Protocol application. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02 https://www.zerodayinitiative.com/advisories/ZDI-21-184 • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 8.8EPSS: 1%CPEs: 4EXPL: 0

The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. El Omron CX-One versiones 4.60 y anteriores es vulnerable a un desbordamiento del búfer en la región stack de la memoria, lo que puede permitir a un atacante ejecutar código arbitrario remotamente This vulnerability allows remote attackers to execute arbitrary code on affected installations of Omron CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of NCI files by the CX-Position application. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02 https://www.zerodayinitiative.com/advisories/ZDI-21-183 https://www.zerodayinitiative.com/advisories/ZDI-21-185 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 8.8EPSS: 0%CPEs: 4EXPL: 0

The Omron CX-One Version 4.60 and prior may allow an attacker to supply a pointer to arbitrary memory locations, which may allow an attacker to remotely execute arbitrary code. Omron CX-One versiones 4.60 y anteriores, puede permitir a un atacante suministrar un puntero a ubicaciones de memoria arbitrarias, lo que puede permitir a un atacante ejecutar código arbitrario remotamente This vulnerability allows remote attackers to execute arbitrary code on affected installations of Omron CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of NCI files by the CX-Position application. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://us-cert.cisa.gov/ics/advisories/icsa-21-007-02 https://www.zerodayinitiative.com/advisories/ZDI-21-182 • CWE-822: Untrusted Pointer Dereference •

CVSS: 7.8EPSS: 2%CPEs: 2EXPL: 0

Three type confusion vulnerabilities exist in CX-One Versions 4.50 and prior and CX-Protocol Versions 2.0 and prior when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application. Existen tres vulnerabilidades de confusión de tipos en CX-One, en versiones 4.50 y anteriores, y en CX-Protocol, en versiones 2.0 y anteriores, durante el procesamiento de archivos de proyecto. Un atacante podría usar un archivo de proyecto especialmente manipulado para explotar y ejecutar código con los privilegios de la aplicación. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One CX-Protocol. • http://www.securityfocus.com/bid/106524 https://ics-cert.us-cert.gov/advisories/ICSA-19-010-02 • CWE-704: Incorrect Type Conversion or Cast CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 0%CPEs: 7EXPL: 0

Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition. El análisis sintáctico de archivos de proyecto mal formados en Omron CX-One, en versiones 4.42 y anteriores, incluyendo las siguientes aplicaciones: CX-FLnet, en versiones 1.00 y anteriores; CX-Protocol, en versiones 1.992 y anteriores; CX-Programmer, en versiones 9.65 y anteriores; CX-Server, en versiones 5.0.22 y anteriores; Network Configurator, en versiones 3.63 y anteriores y Switch Box Utility, en versiones 1.68 y anteriores, podría permitir que el puntero llame a un objeto incorrecto, lo que resulta en un acceso del recurso empleando una condición de tipo incompatible. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PSW files. When parsing a crafted file, the process does not properly validate user-supplied data, which can result in a type confusion condition. • https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02 • CWE-118: Incorrect Access of Indexable Resource ('Range Error') CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •