17 results (0.006 seconds)

CVSS: 9.0EPSS: 0%CPEs: 12EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. • https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 5.5EPSS: 0%CPEs: 12EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. • https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 • CWE-248: Uncaught Exception CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 9.0EPSS: 0%CPEs: 12EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. • https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 • CWE-749: Exposed Dangerous Method or Function •

CVSS: 8.6EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V10, V11, V12 (todas las versiones); SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V13 (todas las versiones anteriores a la V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V14 (todas las versiones anteriores a la V14 SP1 Update 6) y SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (todas las versiones anteriores a la V15 Update 2). • http://www.securityfocus.com/bid/105115 https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf • CWE-276: Incorrect Default Permissions CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 7.8EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V10, V11, V12 (todas las versiones); SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V13 (todas las versiones anteriores a la V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) y WinCC (TIA Portal) V14 (todas las versiones anteriores a la V14 SP1 Update 6) y SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (todas las versiones anteriores a la V15 Update 2). Los permisos de archivo incorrectos en la instalación por defecto de TIA Portal podría permitir que un atacante con acceso al sistema de archivos local inserte archivos especialmente manipulados que podrían evitar el arranque de TIA Portal (denegación de servicio) o conducir a la ejecución de código local. • http://www.securityfocus.com/bid/105115 https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf • CWE-276: Incorrect Default Permissions CWE-732: Incorrect Permission Assignment for Critical Resource •