CVSS: 8.6EPSS: 0%CPEs: 4EXPL: 0

Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A. Una vulnerabilidad de Manejo Faltante en el protocolo de administración propietario (puerto TCP 5558) de Hitachi Energy FOX61x, XCM20 permite que un atacante que explote la vulnerabilidad al activar SSH en el puerto TCP 5558 para causar una interrupción en la comunicación del NMS y NE. Este problema afecta a: Hitachi Energy FOX61x versiones anteriores a la R15A. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000062&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=8DBD000069&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-431: Missing Handler •

CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 0

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions). Una vulnerabilidad de comprobación de entrada inapropiada en el analizador de APDU en la función IEC 60870-5-104 de la interfaz de comunicación bidireccional (BCI) de la serie RTU500 de Hitachi Energy permite a un atacante causar el reinicio de la CMU RTU500 receptora en la que está habilitado el BCI cuando recibe un mensaje especialmente diseñado. Por defecto, la función BCI IEC 60870-5-104 está deshabilitada (no configurada). • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 9.0EPSS: 0%CPEs: 34EXPL: 0

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000058&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=8DBD000059&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=8DBD000060&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-269: Improper Privilege Management CWE-274: Improper Handling of Insufficient Privileges •

CVSS: 8.1EPSS: 0%CPEs: 12EXPL: 0

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions. Una vulnerabilidad Insecure Boot Image en Hitachi Energy Relion Relion 670/650/SAM600-IO series permite que un atacante que consiga acceder al puerto de red frontal y causar una secuencia de reinicio del dispositivo pueda explotar la vulnerabilidad, donde se presenta un pequeño espacio de tiempo durante el proceso de arranque en el que se carga una versión antigua de VxWorks antes del arranque del firmware de la aplicación, podría explotar la vulnerabilidad de la versión antigua de VxWorks y causar una denegación de servicio en el producto. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-1188: Initialization of a Resource with an Insecure Default •

CVSS: 7.2EPSS: 0%CPEs: 2EXPL: 0

Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions. Una vulnerabilidad de control de acceso inapropiado en la autenticación y autorización de la aplicación de Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) permite a un atacante ejecutar un archivo JAR Java Applet firmado modificado. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000067&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=8DBD000068&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-284: Improper Access Control •