Page 10 of 763 results (0.004 seconds)

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-04.pdf • CWE-129: Improper Validation of Array Index •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-04.pdf • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric IGSS. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the processing of commands by the UpdateService service. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-02.pdf • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 0

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Operator Terminal Expert. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of of VXDZ files while in simulation mode. When parsing name:value pairs in configuation data, the process does not properly validate a user-supplied string before executing it as code. An attacker can leverage this vulnerability to execute code in the context of the current user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-01.pdf • CWE-94: Improper Control of Generation of Code ('Code Injection') •