Page 12 of 750 results (0.004 seconds)

CVSS: 7.6EPSS: 0%CPEs: 10EXPL: 0

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulation when malicious code is inserted into the browser. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.7EPSS: 0%CPEs: 1EXPL: 0

A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-06.pdf • CWE-427: Uncontrolled Search Path Element •

CVSS: 8.8EPSS: 0%CPEs: 16EXPL: 0

A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-03.pdf • CWE-287: Improper Authentication •

CVSS: 5.5EPSS: 0%CPEs: 1EXPL: 0

A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf • CWE-269: Improper Privilege Management •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf • CWE-668: Exposure of Resource to Wrong Sphere •