Page 121 of 763 results (0.005 seconds)

CVSS: 10.0EPSS: 0%CPEs: 120EXPL: 0

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. Existen cuentas embebidas en los controladores Modicon Premium, Modicon Quantum, Modicon M340 y BMXNOR0200, de Schneider Electric, en todas las versiones de los módulos de comunicación. • http://www.securityfocus.com/bid/103542 https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01 • CWE-798: Use of Hard-coded Credentials •

CVSS: 9.1EPSS: 0%CPEs: 11EXPL: 0

An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization. Existe una vulnerabilidad de autorización incorrecta en 66074 MGE Network Management Card Transverse, de Schneider Electric, instalados en MGE UPS y MGE STS. El servidor web integrado (Port 80/443/TCP) de los dispositivos afectados podría permitir que un atacante remoto cambie los parámetros UPS de control y cierre u otras opciones críticas sin autorización. • https://www.schneider-electric.com/en/download/document/SEVD-2018-074-01 • CWE-863: Incorrect Authorization •

CVSS: 10.0EPSS: 0%CPEs: 11EXPL: 0

An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system. Existe una vulnerabilidad de omisión de autenticación en 66074 MGE Network Management Card Transverse, de Schneider Electric, instalados en MGE UPS y MGE STS. El servidor web integrado (Port 80/443/TCP) de los dispositivos afectados podría permitir que un atacante remoto obtenga acceso completo al dispositivo omitiendo el sistema de autorización. • https://www.schneider-electric.com/en/download/document/SEVD-2018-074-01 •

CVSS: 7.5EPSS: 0%CPEs: 120EXPL: 0

A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. Existe una vulnerabilidad en los servicios web que procesan peticiones SOAP en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric, que podría conducir a un desbordamiento de búfer. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 6.5EPSS: 0%CPEs: 46EXPL: 0

A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number. Existe una vulnerabilidad de denegación de servicio (DoS) en MiCOM Px4x (excepto el rango P540) con una placa Ethernet heredada, MiCOM P540D Range con una placa Ethernet heredada y MiCOM Px4x Rejuvenated, de Schneider Electric, que podrían perder la comunicación de red en caso de que TCP/IP abra peticiones en el puerto 20000 (DNP3oE) si una sesión TCP/IP más antigua siga abierta con una dirección IP y un número de puerto idénticos. • https://www.schneider-electric.com/en/download/document/SEVD-2018-074-02 https://www.schneider-electric.com/en/download/document/SEVD-2018-074-03 https://www.schneider-electric.com/en/download/document/SEVD-2018-074-04 • CWE-613: Insufficient Session Expiration •