Page 123 of 763 results (0.010 seconds)

CVSS: 9.8EPSS: 0%CPEs: 11EXPL: 0

A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext Existe una vulnerabilidad de transmisión en texto claro de información sensible en 66074 MGE Network Management Card Transverse, de Schneider Electric, instalado en MGE UPS y MGE STS. El servidor web integrado (Puerto 80/443/TCP) de los dispositivos afectados podría permitir que atacantes remotos descubran una cuenta administrativa. Por defecto, si en el dispositivo no se emplea SSL en las opciones y si hay múltiples peticiones de la página "Access Control" (IP-address device/ups/pas_cont.htm), los datos de la cuenta se enviarán en texto claro. • https://www.schneider-electric.com/en/download/document/SEVD-2018-074-01 • CWE-319: Cleartext Transmission of Sensitive Information •

CVSS: 7.5EPSS: 0%CPEs: 120EXPL: 0

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. Existe una vulnerabilidad de desbordamiento de búfer en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric. La vulnerabilidad de desbordamiento de búfer se provoca por el tamaño de la cadena de origen especificada (en lugar del tamaño del búfer) como número de bytes que deben copiarse. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 9.8EPSS: 0%CPEs: 40EXPL: 0

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'. Existe una vulnerabilidad en Pelco Sarix Professional de Schneider Electric en todas las versiones de firmware anteriores a la 3.29.67 que podría permitir la ejecución de comandos debido a la falta de validación de los metacaracteres shell con el valor "model_name" o "'mac_address". • https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01 • CWE-20: Improper Input Validation •

CVSS: 9.8EPSS: 1%CPEs: 40EXPL: 0

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code. Existe una vulnerabilidad de desbordamiento de búfer en la interfaz de usuario web de Pelco Sarix Professional de Schneider Electric en todas las versiones de firmware anteriores a 3.29.67, que podría permitir que un atacante remoto no autenticado ejecute código arbitrario. • https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01 • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 9.1EPSS: 0%CPEs: 40EXPL: 0

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file' Existe una vulnerabilidad en Pelco Sarix Professional de Schneider Electric en todas las versiones de firmware anteriores a la 3.29.67 que podría permitir que un atacante remoto elimine arbitrariamente archivos del sistema debido a la falta de validación de /login/bin/set_param en el nombre de archivo con el valor "system.delete.sd_file". • https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01 • CWE-20: Improper Input Validation •