Page 13 of 119 results (0.016 seconds)

CVSS: 5.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability in the protocol detection component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper detection of the initial use of a protocol on a nonstandard port. An attacker could exploit this vulnerability by sending traffic on a nonstandard port for the protocol in use through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. Once the initial protocol flow on the nonstandard port is detected, future flows on the nonstandard port will be successfully detected and handled as configured by the applied policy. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190816-ftd-nspd • CWE-264: Permissions, Privileges, and Access Controls CWE-287: Improper Authentication •

CVSS: 5.8EPSS: 0%CPEs: 7EXPL: 1

A vulnerability in the stream reassembly component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper reassembly of traffic streams. An attacker could exploit this vulnerability by sending crafted streams through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems that would otherwise be blocked. Una vulnerabilidad en el componente de reensamblado continuo del software Cisco Firepower Threat Defense, el software Cisco FirePOWER Services para ASA y el software Cisco Firepower Management Center, podría permitir a un atacante remoto no autenticado omitir las protecciones de filtrado. • https://www.exploit-db.com/exploits/47902 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190816-ftd-srb • CWE-20: Improper Input Validation CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 4.8EPSS: 0%CPEs: 5EXPL: 0

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based management interface. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting malicious code in certain sections of the interface that are visible to other users. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. An attacker would need valid administrator credentials to exploit this vulnerability. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 7.7EPSS: 0%CPEs: 18EXPL: 0

A vulnerability in the configuration of the Pluggable Authentication Module (PAM) used in Cisco Firepower Threat Defense (FTD) Software, Cisco Firepower Management Center (FMC) Software, and Cisco FXOS Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to improper resource management in the context of user session management. An attacker could exploit this vulnerability by connecting to an affected system and performing many simultaneous successful Secure Shell (SSH) logins. A successful exploit could allow the attacker to exhaust system resources and cause the device to reload, resulting in a DoS condition. To exploit this vulnerability, the attacker needs valid user credentials on the system. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-ftd-fpmc-dos • CWE-400: Uncontrolled Resource Consumption •

CVSS: 4.9EPSS: 0%CPEs: 1EXPL: 0

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to perform a directory traversal attack on an affected device. The vulnerability is due to insufficient input validation by the web-based management interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface. A successful exploit could allow the attacker to bypass Cisco FMC Software security restrictions and gain access to the underlying filesystem of the affected device. Una vulnerabilidad en la interfaz de administración basada en web del Software Cisco Firepower Management Center (FMC), podría permitir a un atacante remoto autenticado realizar un ataque de salto de directorio en un dispositivo afectado. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-dir-trav • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •