Page 13 of 148 results (0.008 seconds)

CVSS: 7.2EPSS: 0%CPEs: 55EXPL: 0

A vulnerability in the software image verification functionality of Cisco IOS XE Software for the Cisco Catalyst 9000 Family of switches could allow an unauthenticated, physical attacker to execute unsigned code at system boot time. The vulnerability is due to an improper check in the code function that manages the verification of the digital signatures of system image files during the initial boot process. An attacker could exploit this vulnerability by loading unsigned software on an affected device. A successful exploit could allow the attacker to boot a malicious software image or execute unsigned code and bypass the image verification check part of the secure boot process of an affected device. To exploit this vulnerability, the attacker would need to have unauthenticated physical access to the device or obtain privileged access to the root shell on the device. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ios-xe-cat-verify-BQ5hrXgH • CWE-347: Improper Verification of Cryptographic Signature •

CVSS: 9.8EPSS: 0%CPEs: 55EXPL: 0

A vulnerability in the Easy Virtual Switching System (VSS) feature of Cisco IOS XE Software for Cisco Catalyst 4500 Series Switches and Cisco Catalyst 4500-X Series Switches could allow an unauthenticated, remote attacker to execute arbitrary code on the underlying Linux operating system of an affected device. The vulnerability is due to incorrect boundary checks of certain values in Easy VSS protocol packets that are destined for an affected device. An attacker could exploit this vulnerability by sending crafted Easy VSS protocol packets to UDP port 5500 while the affected device is in a specific state. When the crafted packet is processed, a buffer overflow condition may occur. A successful exploit could allow the attacker to trigger a denial of service (DoS) condition or execute arbitrary code with root privileges on the underlying Linux operating system of the affected device. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ios-xe-evss-code-exe-8cw5VSvw • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 8.6EPSS: 0%CPEs: 265EXPL: 0

A vulnerability in the DNS application layer gateway (ALG) functionality used by Network Address Translation (NAT) in Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to a logic error that occurs when an affected device inspects certain DNS packets. An attacker could exploit this vulnerability by sending crafted DNS packets through an affected device that is performing NAT for DNS packets. A successful exploit could allow an attacker to cause the device to reload, resulting in a denial of service (DoS) condition on an affected device. The vulnerability can be exploited only by traffic that is sent through an affected device via IPv4 packets. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-alg-dos-hbBS7SZE • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.2EPSS: 0%CPEs: 29EXPL: 0

A vulnerability in the hardware initialization routines of Cisco IOS XE Software for Cisco 1100 Series Industrial Integrated Services Routers and Cisco ESR6300 Embedded Series Routers could allow an authenticated, local attacker to execute unsigned code at system boot time. This vulnerability is due to incorrect validations of parameters passed to a diagnostic script that is executed when the device boots up. An attacker could exploit this vulnerability by tampering with an executable file stored on a device. A successful exploit could allow the attacker to execute unsigned code at boot time and bypass the software image verification check part of the secure boot process of an affected device. To exploit this vulnerability, the attacker would need administrative level credentials (level 15) on the device. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ios-xe-iot-codexec-k46EFF6q • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 7.8EPSS: 0%CPEs: 224EXPL: 0

A vulnerability in a diagnostic command for the Plug-and-Play (PnP) subsystem of Cisco IOS XE Software could allow an authenticated, local attacker to elevate privileges to the level of an Administrator user (level 15) on an affected device. The vulnerability is due to insufficient protection of sensitive information. An attacker with low privileges could exploit this vulnerability by issuing the diagnostic CLI show pnp profile when a specific PnP listener is enabled on the device. A successful exploit could allow the attacker to obtain a privileged authentication token. This token can be used to send crafted PnP messages and execute privileged commands on the targeted system. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ios-xe-pnp-priv-esc-AmG3kuVL • CWE-532: Insertion of Sensitive Information into Log File •