CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 0

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf • CWE-345: Insufficient Verification of Data Authenticity •

CVSS: 5.3EPSS: 0%CPEs: 62EXPL: 0

A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-01.pdf • CWE-116: Improper Encoding or Escaping of Output CWE-117: Improper Output Neutralization for Logs •

CVSS: 7.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SNMPDBManager class. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-798: Use of Hard-coded Credentials •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to localhost interface of the EcoStruxure Power Commission application. Affected Products: EcoStruxure Power Commission (Versions prior to V2.25) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-03_EcoStruxure_Power_Commission_Security_Notification.pdf • CWE-285: Improper Authorization •

CVSS: 7.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the product installer. The product sets incorrect permissions on folders. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •