Page 18 of 763 results (0.004 seconds)

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-102-01_IGSS_Security_Notification_V2.0.pdf • CWE-190: Integer Overflow or Wraparound •

CVSS: 9.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the UpLoadAction class. When parsing the filename parameter, the process does not properly validate user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 7.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the product installer. The product sets incorrect permissions on folders. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 7.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SNMPDBManager class. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-798: Use of Hard-coded Credentials •

CVSS: 9.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows remote attackers to bypass authentication on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the updatePassword function. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-306: Missing Authentication for Critical Function •