Page 2 of 106 results (0.003 seconds)

CVSS: 6.1EPSS: 0%CPEs: 2EXPL: 1

Advantech WebAccess 8.4.2 and 8.4.4 allows XSS via the username column of the bwRoot.asp page of WADashboard. Advantech WebAccess versiones 8.4.2 y 8.4.4, permite ataques de tipo XSS por medio de la columna de nombre de usuario de la página bwRoot.asp de WADashboard • https://github.com/ethancsyang/CveProject/tree/main/CVE-2021-34540 https://www.advantech.com/support • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges. WebAccess Node (todas las versiones anteriores a 9.0.1) presenta permisos incorrectos establecidos para los recursos usados por servicios específicos, lo que puede permitir una ejecución de código con privilegios system • https://us-cert.cisa.gov/ics/advisories/icsa-20-261-01 • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 9.8EPSS: 9%CPEs: 1EXPL: 0

WebAccess Node Version 8.4.4 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. WebAccess Node versión 8.4.4 y anteriores, es vulnerable a un desbordamiento de búfer en la región stack de la memoria, que puede permitir a un atacante ejecutar código arbitrario remotamente This vulnerability allows local attackers to escalate privileges on affected installations of Advantech WebAccess Node. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the PostgreSQL database. The issue results from incorrect permissions set on a resource used by the service. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. • https://www.us-cert.gov/ics/advisories/icsa-20-161-01 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 9.8EPSS: 1%CPEs: 2EXPL: 0

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a low privilege user to overwrite files outside the application’s control. Advantech WebAccess Node, versiones 8.4.4 y anteriores, versión 9.0.0. Se presentan múltiples vulnerabilidades de salto de ruta relativa que pueden permitir a un usuario con poco privilegio sobrescribir archivos fuera del control de la aplicación. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Advantech WebAccess/SCADA. • https://www.us-cert.gov/ics/advisories/icsa-20-128-01 https://www.zerodayinitiative.com/advisories/ZDI-20-589 https://www.zerodayinitiative.com/advisories/ZDI-20-595 https://www.zerodayinitiative.com/advisories/ZDI-20-605 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-23: Relative Path Traversal •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 0

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An out-of-bounds vulnerability exists that may allow access to unauthorized data. Advantech WebAccess Node, versiones 8.4.4 y anteriores, versión 9.0.0. Se presenta una vulnerabilidad de lectura fuera de límites que puede permitir el acceso a datos no autorizados. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Advantech WebAccess/SCADA. • https://www.us-cert.gov/ics/advisories/icsa-20-128-01 https://www.zerodayinitiative.com/advisories/ZDI-20-628 • CWE-125: Out-of-bounds Read •