CVE-2020-27255
https://notcve.org/view.php?id=CVE-2020-27255
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR). Se presenta una vulnerabilidad de desbordamiento de la pila en FactoryTalk Linx versiones 6.11 y anteriores. Esta vulnerabilidad podría permitir a un atacante remoto no autenticado enviar peticiones de atributos de configuración maliciosos, lo que podría resultar en un filtrado de información confidencial. • https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01 • CWE-122: Heap-based Buffer Overflow •
CVE-2020-27253
https://notcve.org/view.php?id=CVE-2020-27253
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device. Se presenta un fallo en la rutina de comprobación de Ingresos y Egresos de FactoryTalk Linx Versiones 6.11 y anteriores. Esta vulnerabilidad podría permitir a un atacante remoto, no autenticado, diseñar específicamente un paquete malicioso resultando en una condición de denegación de servicio en el dispositivo • https://us-cert.cisa.gov/ics/advisories/icsa-20-329-01 • CWE-20: Improper Input Validation •
CVE-2020-12005
https://notcve.org/view.php?id=CVE-2020-12005
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Se presenta una vulnerabilidad en la función de comunicación que permite a los usuarios cargar archivos EDS mediante FactoryTalk Linx. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-434: Unrestricted Upload of File with Dangerous Type •
CVE-2020-12003
https://notcve.org/view.php?id=CVE-2020-12003
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
CVE-2020-12001 – Rockwell Automation FactoryTalk Linx CopyRenameProject Directory Traversal Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2020-12001
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. El mecanismo de análisis que procesa determinados tipos de archivos no proporciona un saneamiento de entrada. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 https://www.zerodayinitiative.com/advisories/ZDI-20-733 • CWE-20: Improper Input Validation •