Page 3 of 12 results (0.002 seconds)

CVSS: 8.1EPSS: 0%CPEs: 4EXPL: 0

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. • https://www.us-cert.gov/ics/advisories/icsa-20-163-02 • CWE-20: Improper Input Validation •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 1

An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation. Un elemento o ruta de búsqueda sin entrecomillar en RSLinx Classic en versiones 3.90.01 y anteriores y FactoryTalk Linx Gateway en versiones 3.90.00 y anteriores podría permitir que un usuario local autorizado sin privilegios ejecute código arbitrario y permita que un actor de amenaza escale sus privilegios de usuario en la estación de trabajo afectada. Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway suffer from a privilege escalation vulnerability. Rockwell Automation RSLinx Classic versions 3.90.01, 3.73.00, 3.72.00, and 2.58.00 are susceptible. Rockwell Automation FactoryTalk Linx Gateway version 3.90.00 is susceptible. • https://www.exploit-db.com/exploits/44892 http://www.securityfocus.com/bid/104415 https://ics-cert.us-cert.gov/advisories/ICSA-18-158-01 • CWE-428: Unquoted Search Path or Element •