Page 2 of 9 results (0.006 seconds)

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx. En todas las versiones de FactoryTalk View SE, después de omitir los mecanismos de corrupción de memoria encontrados en el sistema operativo, un atacante autenticado local puede corromper el espacio de memoria asociado permitiendo una ejecución de código arbitrario. Rockwell Automation recomienda aplicar el parche 1126290. • https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •

CVSS: 5.3EPSS: 5%CPEs: 1EXPL: 0

All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. Todas las versiones de FactoryTalk View SE, divulgan los nombres de host y las rutas de archivos para determinados archivos dentro del sistema. • http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 8.1EPSS: 4%CPEs: 1EXPL: 1

In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs. En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. • http://packetstormsecurity.com/files/160156/Rockwell-FactoryTalk-View-SE-SCADA-Unauthenticated-Remote-Code-Execution.html https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944 https://us-cert.cisa.gov/ics/advisories/icsa-20-170-05 • CWE-264: Permissions, Privileges, and Access Controls CWE-306: Missing Authentication for Critical Function •

CVSS: 6.9EPSS: 0%CPEs: 2EXPL: 0

Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platform before 2.71.00 and FactoryTalk View Studio 8.00.00 and earlier allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. Vulnerabilidad de ruta de búsqueda no confiable en la aplicación Clean Utility en Rockwell Automation FactoryTalk Services Platform anterior a 2.71.00 y FactoryTalk View Studio 8.00.00 y anteriores permite a usuarios locales ganar privilegios a través de un DLL troyano en un directorio no especificado. • https://ics-cert.us-cert.gov/advisories/ICSA-15-062-02 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/646323 •